INTRODUCTION

Little Giant Submersible Effluent Pumps are

recommended for use in basins or lift stations and suitable for pumping sewage, effluent,

wastewater and other non-explosive, non-corrosive liquids with up to 3/4" spherical

solids.
Automatic operation can be achieved with the use of the RFS Remote Float Switch. Other

accessories such as basins, check valves and covers are also available.
Little Giant pumps are carefully packaged, inspected and tested to insure safe operation

and delivery. When you receive your pump, examine it carefully to determine that there

are no broken or damaged parts that may have occurred during shipment. If damage has

occurred, make notation and notify the firm that you purchased the pump from. They will

assist you in replacement or repair, if required.

SAFETY

RISK OF ELECTRIC SHOCK

This pump is supplied with a grounding conductor and grounding-type

attachment plug. To reduce the risk of electric shock, be certain that it is

connected only to a properly grounded, grounding-type receptacle.

Your115V pump is equipped with a 3-prong electrical plug. The third prong is to ground

the pump to prevent possible electrical shock hazard. Do not remove the third prong

from the plug. A separate branch circuit is recommended. Do not use an extension cord.
When a pump is in a basin, etc., do not touch motor, pipes or water until unit is unplugged

or shut off. If shut-off box is not accessible, call the electric company to shut off service to

the house, or call your local fire department for instructions. Failure to follow this warning

can result in fatal electrical shock.
The flexible PVC jacketed cord assembly mounted to the pump must not be modified in

any way, with the exception of shortening the cord to fit into a control panel. Any splice

between the pump and the control panel must be made within a junction box and

mounted outside of the basin, and comply with the National Electrical Code. Do not use

the power cord for lifting the pump.
The pump motor is equipped with an automatic resetting thermal protector and may

restart unexpectedly. Protector tripping is an indication of motor overloading as a result

of excessively high or low voltage, inadequate wiring, incorrect motor connections, or a

defective motor or pump.

OPERATION

TESTING PUMP OPERATION

RFS SERIES SEWAGE EJECTOR PUMPS:
1. These pumps are equipped with a remote float switch.
2. These pumps are installed in a basin with a sealed cover, so switch operation cannot be

observed. The sump cover usually will have a spare hole that is plugged with a rubber

plug. This plug can be removed and switch operation can be observed.

3. Plug power cord and remote float switch power cord into a grounded receptacle

with voltage consistent with pump voltage as indicated on pump nameplate.

4. Run water into basin until pump starts.
5. Be sure gate valve in discharge line is open.
6. Allow pump to operate through several on-off cycles.
MANUAL SEWAGE EJECTOR PUMPS:
The pump cord for these pumps can be plugged directly into a properly grounded receptacle

with voltage consistent with pump nameplate for continuous pump operation.
CAUTION: This type of operation should be used only for emergency use or when a large

volume of water is to be pumped. Pump must not be allowed to run dry. If pump is run

dry, it may damage pump and void the warranty.

MAINTENANCE

If pump does not operate properly, consult the troubleshooting chart. If trouble cannot

be located with these steps shown, consult your pump dealer or take pump to a Little

Giant authorized service center.
CAUTION: When working on pump or switch, always unplug pump power cord in

addition to removing fuse or shutting off circuit breaker before working on pump.

CLEANING IMPELLER AND VOLUTE

1. Remove screws that hold volute to motor housing.
2. Remove volute and clean impeller and volute passage. Do not use strong solvents

on impeller.

3. Be sure impeller turns freely after cleaning.
4. WARNING: DO NOT REMOVE IMPELLER. REMOVAL OF IMPELLER REQUIRES

SPECIAL TOOLS AND IS TO BE DONE ONLY BY AN AUTHORIZED SERVICE CENTER.
DO NOT REMOVE MOTOR HOUSING COVER. WARRANTY IS VOID IF MOTOR

HOUSING COVER, IMPELLER OR SEALS HAVE BEEN REMOVED.

ANY REPAIR ON MOTOR MUST BE DONE BY AN AUTHORIZED LITTLE GIANT

SERVICE CENTER.

SPECIFICATIONS

Discharge Size:

1-1/2" NPT Vertical

Intake Size:

3/4" Screened Opening

Pump Housing:

Cast Iron

Volute:

Cast Iron

Screen:

ABS

Impeller:

Vortex design, with pressure relief vanes

Motor:

Single phase induction, 1750 RPM, with automatic reset

thermal overload protection.

Hardware:

300 Series Stainless Steel

Thrust Bearing:

Double shielded ball

Radial Bearing:

Sleeve - permanent lubrication

Pump Shaft Seal:

Mechanical, spring loaded, stationary carbon with Nitrile

boot and rotating ceramic seat.

Power Cord:

16 AWG 3-conductor, copper, stranded

Cooling:

The motor housing contains a cooling oil to provide

cooling for the motor and to lubricate bearings and seals.

These pumps are capable of operating with the motor

housing partially exposed for extended periods of time,

providing sufficient motor cooling and bearing

lubrication. However, for the best cooling and longest

motor life, the liquid level being pumped should normally

be above the top of the cast iron motor housing.

SAFETY GUIDELINES

1. Read all instructions and Safety Guidelines thoroughly. Failure to follow the guidelines

and instructions could result in serious bodily injury and/or property damage.

2. DO NOT USE TO PUMP FLAMMABLE OR EXPLOSIVE FLUIDS SUCH AS

GASOLINE, FUEL OIL, KEROSENE, ETC. DO NOT USE IN EXPLOSIVE

ATMOSPHERES OR HAZARDOUS LOCATIONS AS CLASSIFIED BY NEC,

ANSI/NFPA70. FAILURE TO FOLLOW THIS WARNING CAN RESULT IN

PERSONAL INJURY AND/OR PROPERTY DAMAGE.

3. During normal operation the sump pump is immersed in water. Also, during rain

storms, water may be present in the surrounding area of the pump. Caution must be

used to prevent bodily injury when working near the pump:
a. The plug must be removed from the receptacle prior to touching, servicing or

repairing the pump.

b. To minimize possible fatal electrical shock hazard, extreme care should be

used when changing fuses. Do not stand in water while changing fuses or

insert your finger into the fuse socket.

4. Do not run the pump in a dry basin. If the pump is run in a dry basin, the surface

temperature of the pump will rise to a high level. This high level could cause skin

burns if the pump is touched and will cause serious damage to your pump.

5. Do not oil the motor. The pump housing is sealed. A high grade dielectric oil devoid

of water has been put into the motor housing at the factory. Use of other oil could

cause serious electric shock and/or permanent damage to the pump.

6. This pump’s motor housing is filled with a dielectric oil for motor heat transfer and

lifetime lubrication of the bearings. This oil is non-toxic to aquatic life. However,

suffocation can occur if oil is left on the water surface. If oil escapes the motor

housing it can be removed from the surface quickly by placing newspapers on the

water surface to soak up the oil.

7. In any installations where property damage and/or personal injury might result from

an inoperative or leaking pump due to power outages, discharge line blockage, or

any other reason, a backup system(s) and/or alarm should be used.

INSTALLATION

Pump must be installed in a suitable gas tight basin which is at least 18" in diameter and

24" deep.
Pumps features a 1-1/2" female NPT discharge.
Pump can be installed with ABS, PVC, polyethylene or galvanized steel pipe. Proper

adapters are required to connect plastic pipe to pump.
Pump must be placed on a hard level surface. Never place pump directly on clay, earth or

gravel surfaces.

Little Giant Pump Company

P. O. Box 12010

Oklahoma City, OK 73157-2010

405.947.2511

Fax: 405.947.48720

Submersible Effluent Pump

Pompe Pour Effluent

Submersible

Bomba Efluente Sumergible

9E-CIA-RFS

Little

Pump Company

GIANT

9E SERIES • SÉRIE 9E • SERIE 9E

9.60"

Discharge

Sortie

Descarga

1-1/2" (po) NPT

3.00"

Screen to pass 3/4" solids

Écran laissant passer des solides de 3/4 po

Pantalla para pasar sólidos de 3/4 de pulgada

9.60"

6.90"

4.65"

15 ft. Power Cord

Cordon d’alimentation de 15 pi

Cordón de suministro de

energía de 15 pies.

Summary of Contents for 9E Series

Page 1: ...IRES SPECIALTOOLSANDISTOBEDONEONLYBYANAUTHORIZEDSERVICECENTER DO NOT REMOVE MOTOR HOUSING COVER WARRANTY IS VOID IF MOTOR HOUSING COVER IMPELLER OR SEALS HAVE BEEN REMOVED ANY REPAIR ON MOTOR MUST BE...

Page 2: ...ove noted Little Giant products is guaranteed to be in perfect condition when it leaves our factory During the time periods and subject to the conditions hereinafter set forth LITTLEGIANTPUMPCOMPANY S...

Page 3: ...squ une pompe est dans un r servoir viter de toucher au moteur aux tuyaux ou l eau si la pompe n est pas d branch e ou hors tension Si le panneau lectrique n est pas accessible communiquer avec votre...

Page 4: ...se le cylindre baisse aussi et lorsqu il revient environ 45 l interrupteur ouvre le circuit et la pompe s arr te REMARQUE S ASSURER QUE LA POMPE EST SOLIDEMENT INSTALL E DANS LE R SERVOIR ET QU AUCUN...

Page 5: ...n Adresser toute remarque etc Service Department LITTLE GIANT PUMP COMPANY 301 N MacArthur Oklahoma City OK 73127 6616 U S A D TERMINATION DE LA DATE DE FABRICATION 9 87 Le mois et l ann e estampill s...

Page 6: ...SIVOS O LUGARES EPLIGROSOS SEGUN LA CLASIFICACION DEL CODIGO ELECTRICO NACIONAL NEC Y LA NORMA NFPA70 DEL INSTITUTO NACIONAL NORTEAMERICANO DE NORMAS EL HACER CASO OMISO DE ESTA ADVERTENCIA PUEDE TRAE...

Page 7: ...nados por no instalar operar o mantener la unidad conforme a las instrucciones escritas provistas 2 a fallas causadas por abuso accidente o negligencia 3 a servicios normales de mantenimiento y a las...

Page 8: ...do cero Loose connection in level control wiring Connexion des fils lectriques du niveau de contr le distendue Conexiones flojas en los cables del regulador de nivel Check control wiring V rifier le c...