Double Float Tether Length Measurements

The double float pumping range is adjustable from 1.75 to 48 inches. The tether lengths are typically 3.5 
inches. 

SAFETY INSTRUCTIONS

This equipment should be installed and serviced by technically qualified personnel who are familiar with 
the correct selection and use of appropriate tools, equipment, and procedures. Failure to comply with 
national and local electrical and plumbing codes and within Little Giant recommendations may result in 
electrical shock or fire hazard, unsatisfactory performance, or equipment failure.
Know the product’s application, limitations, and potential hazards. Read and follow instructions carefully to 
avoid injury and property damage. Do not disassemble or repair unit unless described in this manual.
Refer to product data plate(s) for additional precautions, operating instructions, and specifications.
Failure to follow installation or operation procedures and all applicable codes may result in the following 
hazards:

Risk of death, personal injury, or property damage due to explosion, 

fire, or electric shock.

• Do not use in flammable, combustible, or explosive fluids such as gasoline, fuel oil, kerosene, etc.

• Do not use in explosive atmospheres or hazardous locations as classified by the NEC, ANSI/NFPA70.

• Do not handle a switch or pump or pump motor with wet hands, or when standing on a wet or damp surface, or 

in water.

• When a pump is in its application, do not touch the motor, pipes, or water until the unit is unplugged or electri

-

cally disconnected.

• If the power disconnect is out of sight, lock it in the open position and tag it to prevent unexpected application of 

power.

• If the disconnect panel is not accessible, contact the electric company to stop service.

High voltages capable of causing severe injury or death by electrical 

shock are present in this unit.

• To reduce risk of electrical shock, disconnect power before working on or around the system. More than one dis

-

connect switch may be required to de-energize the equipment before servicing.

• Some products are supplied with a grounding conductor and grounding-type attachment plug. To reduce risk of 

electric shock, be certain that they are connected only to a properly grounded grounding-type receptacle. Do not 

remove the third prong from the plug. The third prong is to ground the pump and switch to help prevent possible 

electric shock hazard. Do not use an extension cord.

• Check electrical outlets with a circuit analyzer to ensure power, neutral, and ground wires are properly con

-

nected. If not, a qualified, licensed electrician should correct the problem.

• Wire switch and pump system for correct voltages.

• The flexible jacketed cord assembly mounted to the switch must not be modified in any way, with the exception 

of shortening the cord to fit into a control panel. Any splice between the switch and the control panel must be 

made within a junction box mounted outside of the basin and comply with the National Electrical Code. Employ a 

licensed electrician.

• Check local electrical and building codes before installation. The installation must be in accordance with their 

regulations as well as the most recent National Electrical Code (NEC).

• Do not remove the third prong from the plug, or cut plug from cord. These actions will void the warranty.

Summary of Contents for 15DFMMD1WP

Page 1: ...lete warranty informa tion refer to www littlegiant com Specifications Tethered Mechanical Float Switch Double Tethered Mechanical Float Switch RFSN Tether Length Measurements Model No Cord Length ft...

Page 2: ...d If the power disconnect is out of sight lock it in the open position and tag it to prevent unexpected application of power If the disconnect panel is not accessible contact the electric company to s...

Page 3: ...ntal abilities or lacking in experience and expertise unless supervised or instructed Children may not use the equipment nor may they play with the unit or in the immediate vicinity Equipment can star...

Page 4: ...not mount floats in path of incoming liquid and turbulent areas Ensure floats cannot reach pump inlet Electrical Connections Connect the switch and pump power cords to a constant source of power match...

Page 5: ...nhibit switch operation Verify the ON OFF levels are within specification 7 Confirm that there are no leaks in the pump discharge plumbing and main home drain pipe plumbing 8 Allow the pump to operate...

Page 6: ...022 Franklin Electric Co Inc All rights reserved Troubleshooting Problem Probable Causes Corrective Action Pump does not turn on Accumulation of trash on float Clean float Float obstruction Check floa...

Page 7: ...re la garant a con sulte www littlegiant com Especificaciones Interruptor flotante mec nico atado Interruptor flotante mec nico atado doble Mediciones de longitud de la correa RFSN Modelo Longitud del...

Page 8: ...i n de alimentaci n est fuera del sitio bloqu ela en la posici n abierta y etiqu tela para evitar una conexi n inesperada de la alimentaci n Esta unidad tiene voltajes elevados que son capaces de prov...

Page 9: ...citaci n salvo que est n bajo supervisi n oinstrucci n Los ni os no podr n usar el equipo ni jugar con la unidad o en las cercan as inmediatas El equipo puede encenderse en forma autom tica Siempre de...

Page 10: ...sito nien ninguna otra obstrucci n No monte flotadores en elpaso del l quido entrante ni en reas turbulentas Cerci rese de que los flotadores no alcancen la entrada de la bomba Conexiones el ctricas C...

Page 11: ...asta que la bomba se active 6 Confirme que la bomba y su interruptor de control est n funcionando correctamente Confirme que no haya obstrucciones posibles que pudieran impedir el funcionamiento del i...

Page 12: ...ante de inmediato si detecta alg n da o Cerci rese de que el flotador pueda moverse libremente y que el interruptor funcione correcta mente Soluci n de problemas Problema Causas probables Acci n corre...

Page 13: ...sur la garantie consultez www littlegiant com Sp cifications Interrupteur flotteur m canique avec attache Double interrupteur flotteur m canique avec attache Mesures de longueur d attache RFSN Mod le...

Page 14: ...toute mise sous tension inopin e Si le panneau du disjoncteur n est pas accessible contacter la compagnie d lectricit afin que le courant soit coup Cet appareil contient des tensions lev es susceptib...

Page 15: ...uf si ces personnes sont super vis es ou ont re u des instructions cet effet Les enfants ne doivent pas utiliser l quipement ni jouer avec l appareil ou dans sa proximit imm diate L quipement peut d m...

Page 16: ...lez pas de flotteurs dans le chemin du liquide entrant et des zones turbulentes Assurez vous que les flotteurs ne peuvent pas atteindre l entr e de la pompe Connexions lectriques Raccordez le cordon d...

Page 17: ...rmez que la pompe et son interrupteur de commande fonctionnent comme ils le devraient Assurez vous qu aucune obstruction ventuelle n est susceptible d entraver le fonctionnement de l interrupteur V ri...

Page 18: ...ur fonctionne correctement D pannage Probl me Causes probables Mesure Corrective La pompe ne d marre pas Accumulation de d chets sur le flotteur Nettoyez le flotteur Obstruction du flotteur V rifiez l...

Page 19: ...19 REMARQUES...

Page 20: ...ic Co Inc Oklahoma City OK 73157 2010 800 701 7894 littlegiant com Pour l aide technique entrez s il vous pla t en contact Droits d auteur 2022 Franklin Electric Co Inc Tous droits r serv s 1000001135...

Reviews: