BEFORE GETTING STARTED

READ THESE INSTRUCTIONS CAREFULLY BEFORE ATTEMPTING TO INSTALL, OPERATE, OR SERVICE YOUR PRODUCT. KNOW THE PRODUCT’S APPLICATION, 
LIMITATIONS, AND POTENTIAL HAZARDS. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH THESE 
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
Refer to product data plate(s) for additional operating instructions and specifications. 

This is the safety alert symbol. When you see this

s

!

symbol on your pump or in this manual, look for one of the following signal words and be alert to the 

potential for personal injury or property damage if ignored: 

s

!

DANGER

 warns about hazards that will cause serious personal injury, death or major property damage if ignored.

s

!

WARNING

 warns about hazards that can cause serious personal injury, death or major property damage if ignored.

s

!

CAUTION

 warns about hazards that will or can cause minor personal injury or major property damage if ignored.

s

!

NOTICE

 indicates special instructions which are important but not related to hazards. Carefully read and follow all safety instructions in 

this manual and on pump.

s

!

DANGER

 DO NOT USE TO PUMP FLAMMABLE OR EXPLOSIVE FLUIDS SUCH AS GASOLINE, FUEL OIL, KEROSENE, ETC. DO NOT USE IN  

EXPLOSIVE ATMOSPHERES OR HAZARDOUS LOCATIONS AS CLASSIFIED BY THE NEC, ANSI/NFPA70. FAILURE TO FOLLOW THIS WARNING CAN RESULT IN  

PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. DO NOT HANDLE A PUMP OR PUMP MOTOR WITH WET HANDS OR WHEN STANDING ON A WET OR  

DAMP SURFACE, OR IN WATER. FAILURE TO FOLLOW THIS WARNING CAN RESULT IN FATAL ELECTRICAL SHOCK. PUMP SHOULD ONLY BE USED WITH  

LIQUIDS COMPATIBLE WITH PUMP COMPONENT MATERIALS.

s

!

WARNING

 Make certain that the unit is disconnected from the power source before attempting to service or remove any 

component. If the power disconnect is out of sight, lock it in the open position and tag it to prevent unexpected application of power.

s

!

WARNING

 This equipment should be installed and serviced by technically qualified personnel. Comply with national and local 

electrical and plumbing codes when installing this unit. Failure to install it in compliance with national and local electrical and plumbing codes and within 

Franklin Electric’s recommendations may result in electrical shock or fire hazard, unsatisfactory performance, or equipment failure. Installation information  

is available through pump manufacturers and distributors, or directly from Franklin Electric at our toll-free number 1-800-701-7894.

This equipment must not be used by children or persons with reduced physical, sensory or mental abilities, or lacking in experience and expertise,  

unless supervised or instructed. Children may not use the equipment, nor may they play with the equipment or in the immediate vicinity.

s

!

CAUTION

 In any installations where property damage and/or personal injury might result from an inoperative or leaking pump due 

to power outages, discharge line blockage, or any other reason, a backup system(s) and/or alarm should be used.

•  Keep work area clean, well-lit, and uncluttered.
•  Keep safety labels clean and in good condition.
•  Do not run pump dry. For optimal cooling and to prolong the motor life, 

the liquid level being pumped should normally be above the top of the 

pump housing.

•  Wear safety glasses while installing or performing maintenance on pump.
•  Make sure all 

ELECTRICAL POWER IS OFF

 before connecting any electrical 

wires. Wire sump pump system for correct voltages. Follow all pump 

wiring instructions provided in the “Wiring” section of this manual

s

 

CAUTION

!

W A R N I N G

W A R N I N G

Summary of Contents for 10EC-CIA-SFS

Page 1: ...STOCK No 53DH04 MODEL 6EC CIA SFS STOCK No 53DH05 MODEL 6EC CIM STOCK No 53DH06 MODEL 10EC CIA SFS Installation Guide ...

Page 2: ...NGMake certain that the unit is disconnected from the power source before attempting to service or remove any component If the power disconnect is out of sight lock it in the open position and tag it to prevent unexpected application of power s WARNINGThis equipment should be installed and serviced by technically qualified personnel Comply with national and local electrical and plumbing codes when...

Page 3: ...rted 2 Introduction 4 Safety Guidelines 4 Installation 5 Typical Installation 6 Wiring 7 Specifications 7 Sump System Operation Testing 8 Maintenance 9 Pump Performance Curves 10 Troubleshooting 10 Replacement Parts 11 Limited Warranty 15 ...

Page 4: ...they are not call a qualified licensed electrician s WARNINGThe pump motor is equipped with an automatic resetting thermal protector and may restart unexpectedly Protector tripping is an indication of motor overloading overheating which can be caused by application issues such as an obstructed pump impeller switch stuck in ON position pump running dry pump air locked pump short cycling excessively...

Page 5: ... comes with 1 1 2 female pipe thread discharge a Support pump and piping when assembling and when installed Failure to do so may cause piping to break pump to fail motor bearing failures etc b Always install a union in the discharge line just above the sump pit to allow for easy removal of the pump for cleaning or repair 6 A check valve must be used in the discharge line to prevent back flow of li...

Page 6: ...mp outlet Pump Power Grommet Sump Cover 2 or 3 Vent Pipe 3 16 dia Bleed Hole in Discharge Pipe Gas tight Basin 18 dia x 24 deep min Union Check Valve Gate Valve Pump Place pump on hard level surface Never place directly on clay earth or gravel surface SFS Models 7 10 on level SFS Models 2 5 off level TYPICALINSTALLATION ...

Page 7: ...ump must not be modified in any way with the exception of shortening the cord to fit into a control panel Any splice between the pump and the control panel must be made within a junction box and mounted outside of the basin and comply with the National Electrical Code Do not use the power cord for lifting the pump SPECIFICATIONS Gallons Per Minute at Height Liters Per Minute at Height Shut Off 5 1...

Page 8: ...rol The pump cord for these pumps can be plugged directly into a properly grounded receptacle with voltage consistent with pump nameplate for continuous pump operation a s CAUTIONThis type of operation should be used only for emergency use or when a large volume of water is to be pumped The pump must be continuously monitored during operation and disconnected from power before the pump runs dry b ...

Page 9: ...are fully engaged with plumbing and fully tightened 6 Test operation of the sump system following the instructions outlined in the Sump System Operation Testing section of this manual 7 While the pump is running make sure a stream of water is escaping from the air bleed hole a If not clear the hole of any deposits or debris CLEANING IMPELLER AND VOLUTE Periodic cleaning of the pump parts will prol...

Page 10: ...installed properly Check valve stuck or plugged Remove check valve and inspect for proper operation Lift too high for pump Check rating table Inlet to impeller plugged Pull pump and clean Pump is air locked Pull pump and clean Pump does not deliver rated capacity Lift too high for pump Check rated pump performance Low voltage speed too slow Check for proper supply voltage to make certain it corres...

Page 11: ...itch 20 Cord 1 110970103 Cover Assembly 115 V Manual 20 Cord 1 110970201 Capacitor Kit 115 V with Bracket Seal Ring 2 110970301 Float Assembly with Stem Strap 3 110970401 Volute Base Plastic with Gasket for 6E 4 110970403 Volute Base Plastic with Gasket for 10EC 4 REPLACEMENTPARTS ...

Page 12: ...12 NOTES ...

Page 13: ...13 NOTES ...

Page 14: ...14 ...

Page 15: ...cordance with the Company s published instructions applicable codes applicable ordinances and or with generally accepted industry standards 3 Any product that has been subject to misuse misapplication neglect alteration accident abuse tampering acts of God including lightning acts of terrorism acts of war fire improper storage or installation improper use improper maintenance or repair damage or c...

Page 16: ...OSSIBLE THIS PARAGRAPH SHALL ALSO APPLY TO ALL DAMAGES RESULTING FROM CONDITIONS SET FORTH IN SECTION III ABOVE AND 1 DEFECTS IN PRODUCT PROTOTYPES OR REPLACEMENT PART PROTOTYPES THAT HAVE NOT BEEN PUT INTO PRODUCTION CIRCULATED AND SOLD BY THE COMPANY AND OR 2 DEFECTS THAT WERE NOT FOUND AT THE TIME OF SALE DUE TO SCIENTIFIC AND TECHNOLOGICAL REASONS This Limited Warranty gives you specific legal...

Reviews: