background image

11

Part No.

Description

Item No. 

110970101

Cover Assembly, 115 V, Automatic, with Switch, 20' Cord

1

110970103

Cover Assembly, 115 V, Manual, 20' Cord

1

110970201

 Capacitor Kit, 115 V, with Bracket, Seal Ring

2

110970301

Float Assembly with Stem Strap

3

110970401

Volute Base, Plastic, with Gasket for 6E

4

110970403

Volute Base, Plastic, with Gasket for 10EC

4

REPLACEMENT PARTS

Summary of Contents for 10EC-CIA-SFS

Page 1: ...STOCK No 53DH04 MODEL 6EC CIA SFS STOCK No 53DH05 MODEL 6EC CIM STOCK No 53DH06 MODEL 10EC CIA SFS Installation Guide ...

Page 2: ...NGMake certain that the unit is disconnected from the power source before attempting to service or remove any component If the power disconnect is out of sight lock it in the open position and tag it to prevent unexpected application of power s WARNINGThis equipment should be installed and serviced by technically qualified personnel Comply with national and local electrical and plumbing codes when...

Page 3: ...rted 2 Introduction 4 Safety Guidelines 4 Installation 5 Typical Installation 6 Wiring 7 Specifications 7 Sump System Operation Testing 8 Maintenance 9 Pump Performance Curves 10 Troubleshooting 10 Replacement Parts 11 Limited Warranty 15 ...

Page 4: ...they are not call a qualified licensed electrician s WARNINGThe pump motor is equipped with an automatic resetting thermal protector and may restart unexpectedly Protector tripping is an indication of motor overloading overheating which can be caused by application issues such as an obstructed pump impeller switch stuck in ON position pump running dry pump air locked pump short cycling excessively...

Page 5: ... comes with 1 1 2 female pipe thread discharge a Support pump and piping when assembling and when installed Failure to do so may cause piping to break pump to fail motor bearing failures etc b Always install a union in the discharge line just above the sump pit to allow for easy removal of the pump for cleaning or repair 6 A check valve must be used in the discharge line to prevent back flow of li...

Page 6: ...mp outlet Pump Power Grommet Sump Cover 2 or 3 Vent Pipe 3 16 dia Bleed Hole in Discharge Pipe Gas tight Basin 18 dia x 24 deep min Union Check Valve Gate Valve Pump Place pump on hard level surface Never place directly on clay earth or gravel surface SFS Models 7 10 on level SFS Models 2 5 off level TYPICALINSTALLATION ...

Page 7: ...ump must not be modified in any way with the exception of shortening the cord to fit into a control panel Any splice between the pump and the control panel must be made within a junction box and mounted outside of the basin and comply with the National Electrical Code Do not use the power cord for lifting the pump SPECIFICATIONS Gallons Per Minute at Height Liters Per Minute at Height Shut Off 5 1...

Page 8: ...rol The pump cord for these pumps can be plugged directly into a properly grounded receptacle with voltage consistent with pump nameplate for continuous pump operation a s CAUTIONThis type of operation should be used only for emergency use or when a large volume of water is to be pumped The pump must be continuously monitored during operation and disconnected from power before the pump runs dry b ...

Page 9: ...are fully engaged with plumbing and fully tightened 6 Test operation of the sump system following the instructions outlined in the Sump System Operation Testing section of this manual 7 While the pump is running make sure a stream of water is escaping from the air bleed hole a If not clear the hole of any deposits or debris CLEANING IMPELLER AND VOLUTE Periodic cleaning of the pump parts will prol...

Page 10: ...installed properly Check valve stuck or plugged Remove check valve and inspect for proper operation Lift too high for pump Check rating table Inlet to impeller plugged Pull pump and clean Pump is air locked Pull pump and clean Pump does not deliver rated capacity Lift too high for pump Check rated pump performance Low voltage speed too slow Check for proper supply voltage to make certain it corres...

Page 11: ...itch 20 Cord 1 110970103 Cover Assembly 115 V Manual 20 Cord 1 110970201 Capacitor Kit 115 V with Bracket Seal Ring 2 110970301 Float Assembly with Stem Strap 3 110970401 Volute Base Plastic with Gasket for 6E 4 110970403 Volute Base Plastic with Gasket for 10EC 4 REPLACEMENTPARTS ...

Page 12: ...12 NOTES ...

Page 13: ...13 NOTES ...

Page 14: ...14 ...

Page 15: ...cordance with the Company s published instructions applicable codes applicable ordinances and or with generally accepted industry standards 3 Any product that has been subject to misuse misapplication neglect alteration accident abuse tampering acts of God including lightning acts of terrorism acts of war fire improper storage or installation improper use improper maintenance or repair damage or c...

Page 16: ...OSSIBLE THIS PARAGRAPH SHALL ALSO APPLY TO ALL DAMAGES RESULTING FROM CONDITIONS SET FORTH IN SECTION III ABOVE AND 1 DEFECTS IN PRODUCT PROTOTYPES OR REPLACEMENT PART PROTOTYPES THAT HAVE NOT BEEN PUT INTO PRODUCTION CIRCULATED AND SOLD BY THE COMPANY AND OR 2 DEFECTS THAT WERE NOT FOUND AT THE TIME OF SALE DUE TO SCIENTIFIC AND TECHNOLOGICAL REASONS This Limited Warranty gives you specific legal...

Reviews: