1
Mount to ceiling structure with flanges on
channel bars resting against the bottom faces
of the joists. Drive included nail into joist to
secure. Move vertical adjustment to lowest
point. For WALLWASH applications, ensure the
junction box is oriented either directly toward
or away from the washed wall. Trim rotates
only in 180
0
.
D) Non-accessible Ceiling Installation (e.g. plaster, drywall, etc.)
5
Bend (4) bar hangers per fixture at right
angles at the row of (3) holes 2 inches from
one end of the bar hangers to attach to
ceiling joists.
4
4
3
Alternate bar hangers used for EL/ELR:
Attach the adjustable brackets to the fixture
using the hardware provided. Wing nuts
should face inward for adjustment through
the ceiling.
Place (2) hanger bars together so that the
formed tabs engage the slots to form one
long rigid hanger bar. Aligning the ”V”
cutouts in the hanger bar will set the
spacing for a 24” ceiling.
6
Secure channel bars to Hat Channel by
means of a fastener (wire ties, screws, etc.)
2
Secure channel bars to Hatch Channel by
means of a fastener (wire ties, screws, etc.)