Problem: 

Fan fails to operate.

Solutions:

1. Check wall switch to fan.
2. Verify that reverse switch is set completely in 
either direction.
3. Check to be sure fan is wired properly.

Problem: 

Light kit (optional) not lighting.

Solutions:

1. Check wall switch to fan.
2. Check that bulbs are installed correctly.
3. Verify that wires in outlet box are wired 
properly.
4. Verify that molex connections in switch 
housing are connected properly.

Problem: 

Fan operates but light fails (if 

applicable).

Solutions: 

1. Check that bulbs are installed correctly.
2. Verify that wires in outlet box are wired 
properly.
3. Verify that molex connections in switch 
housing are connected properly. 
4. Replace defective bulbs with same type of bulb.

Problem: 

Fan wobbles.

Solutions:

1. Use the balancing kit provided in one of the 
hardware packs. 

If no blade balancing kit is 

provided, please call Customer Support, 
at 1-800-527-1292, to request one.

2. Carefully loosen motor housing and verify that 
hanging bracket is secure. 
3. Check to be sure motor housing is turned 
completely and that motor housing screws are 
secure.

PWLI1801

Parts Replacement.

For parts and information, please refer to
"Parts Inventory" on page 2.
Litex Customer Support:

1-800-527-1292

LITEX 30-YEAR LIMITED WARRANTY:
LITEX INDUSTRIES, LTD. warrants this fan to the original 
household purchaser for indoor use under the following 
provisions:
1-YEAR WARRANTY: LITEX INDUSTRIES, LTD. will replace or 
repair any fan which has faulty performance due to a 
defect in material or workmanship. Contact Litex Customer 
Service at 

1-800-527-1292

 to arrange for return of fan. 

Return fan, shipping prepaid, to Litex Industries, Ltd. We will 
repair or ship you a replacement fan, and we will pay the 
return shipping cost.
5-YEAR WARRANTY: LITEX INDUSTRIES, LTD. will repair or 
replace, at no charge to the original purchaser, any fan 
motor that fails to operate satisfactorily when failure 
results from normal use.
RETURN FAN MOTOR ONLY, shipping prepaid, to Litex 
Industries. We will repair or ship purchaser a replacement 
motor and Litex will pay the return shipping cost.
6-YEAR to 30-YEAR LIMITED WARRANTY: LITEX INDUSTRIES, 
LTD. will repair the fan, at no charge to the original 
purchaser for labor only, if the fan motor fails to operate 
satisfactorily when failure results from normal use. Parts 
used in the repair will be billed to the purchaser at 
prevailing prices at time of repair.
    The purchaser shall be responsible for all costs incurred 
in the removal, reinstallation and shipping of the product 
for repairs.
    This warranty does not apply when damage from 
mechanical, physical, electrical or water abuse results in 
causing the malfunction. Deterioration of finishes or other 
parts due to time or exposure to salt air is specifically 
exempted under this warranty.
    Neither Litex Industries nor the manufacturer will 
assume any liability resulting from improper installation or 
use of this product. In no case shall the company be liable 
for any consequential damages for breach of this, or any 
other warranty expressed or implied whatsoever. This 
limitation as to consequential damages shall not apply in 
states where prohibited.

Summary of Contents for RG52BNK5L

Page 1: ...ring pg 4 Fan Assembly pg 5 Motor Housing Assembly pg 5 Blade Assembly pg 6 Light Kit Assembly Optional pgs 6 8 Testing Your Fan pg 8 Troubleshooting pg 9 Parts Replacement pg 9 Warranty pg 9 Installa...

Page 2: ...wire is larger than 12 gauge or there is more than one house wire to connect to the two fan lead wires consult an electrician for the proper size wire connectors to use 5 Electrical diagrams are for r...

Page 3: ...parts have been included 2 Parts Inventory a hanging bracket 1 piece b motor housing 1 piece c motor assembly 1 piece d light kit fitter 1 piece e finial plate pre attached to light kit fitter 1 piece...

Page 4: ...is suitable for room sizes up to 400 square feet 37 2 square meters Turn off circuit breakers to current fixture from breaker panel and be sure operating light switch is turned to the OFF position WAR...

Page 5: ...tions comply with Local Codes or Ordinances and the National Electrical Code If you are unfamiliar with electrical wiring or if the house building wires are different colors than those referred to bel...

Page 6: ...otor assembly motor mounting nuts and flat washers j hook 7 Motor Housing Assembly Temporarily raise motor housing to hanging bracket to determine which 2 screws in hanging bracket align with slotted...

Page 7: ...rocedure with remaining blade arms Secure all screws NOTE Tighten blade arm screws twice a year Remove 3 screws and star washers from switch housing cap at top of light kit fitter save for later use I...

Page 8: ...up gently until threaded rod comes through hole Replace hex nut on threaded rod Tighten hex nut but DO NOT OVERTIGHTEN hex nut as glass may crack or break Align hole in center of finial plate with thr...

Page 9: ...ull chain in the middle diagram 1 If fan and or light do does not function please refer to Troubleshooting section to solve any issues before contacting Customer Service Turn fan completely off before...

Page 10: ...performance due to a defect in material or workmanship Contact Litex Customer Service at 1 800 527 1292 to arrange for return of fan Return fan shipping prepaid to Litex Industries Ltd We will repair...

Reviews: