Max String Length @
120vac
Max String Length @
277vac
STIK
75 feet
(Max
Modules (21) 40”
or (42) 20” or
combination not to
exceed 75 feet.
170 feet
(Max Modules (50) 40”
or (100 20”) or
combination not to
exceed 170 feet.
1.
STRINGS of lights are connected using quick
connectors. Each MODULE or ASSEMBLY will
plug into the next MODULE or ASSEMBLY
with a quick disconnect. Each STRING will
have 3 types of MODULES or ASSEMBLIES - a
starter MODULE or ASSEMBLY which will
have a pigtail to wire to a junction box on one
end, a middle MODULE or ASSEMBLY which
will have a quick connector on both ends and
an end MODULE or ASSEMBLY which will
have a quick connector on one end and an
end plate on the other end. MODULES,
ASSEMBLIES AND STRINGS MUST NOT BE
UNPLUGGED OR PLUGGED TOGETHER
WHILE POWER IS APPLIED.
2.
Only the starter MODULE is connected to
power. On the starter MODULE or
ASSEMBLY, secure the pigtail cable using an
UL approved wet location cable gland and a
UL rated wet location electrical box. Use
wire connectors to join power side black wire
to BriteCor module or unit black wire, power
side white wire to BriteCor module or unit
white wires. Connect green wires to ground.