LiteSheet Solutions 

 

Page 

5

 of 

6

 

 

 

Max String Length @ 

120vac 

Max String Length @ 

277vac 

STIK 

75 feet  

(Max 

Modules (21) 40” 

or (42) 20” or 

combination not to 

exceed 75 feet. 

170 feet 

 

(Max Modules (50) 40” 

or (100 20”) or 

combination not to 

exceed 170 feet. 

 

1.

 

STRINGS of lights are connected using quick 
connectors.  Each MODULE or ASSEMBLY will 

plug into the next MODULE or ASSEMBLY 
with a quick disconnect.  Each STRING will 

have 3 types of MODULES or ASSEMBLIES - a 
starter MODULE or ASSEMBLY which will 

have a pigtail to wire to a junction box on one 
end, a middle MODULE or ASSEMBLY which 

will have a quick connector on both ends and 
an end MODULE or ASSEMBLY which will 

have a quick connector on one end and an 
end plate on the other end.   MODULES, 

ASSEMBLIES AND STRINGS MUST NOT BE 

UNPLUGGED OR PLUGGED TOGETHER 
WHILE POWER IS APPLIED.  

 

2.

 

Only the starter MODULE is connected to 

power.  On the starter MODULE or 
ASSEMBLY, secure the pigtail cable using an 

UL approved wet location cable gland and a 
UL rated wet location electrical box.   Use 

wire connectors to join power side black wire 
to BriteCor module or unit black wire, power 

side white wire to BriteCor module or unit 
white wires.  Connect green wires to ground.   

 

 

Summary of Contents for BriteCor AC Direct BSS

Page 1: ...BSS BriteCor AC Direct Damp Location Stik Installation Manual ...

Page 2: ... Do not connect this Luminaire to an electrical system that does not provide means for equipment grounding Never use a fixture in a two wire system that is not grounded If dimming functionality is included use only with Litesheet approved dimmers Do not use excessive force when manipulating cables and wires WARNING To prevent wiring damage or abrasion do not pinch wires between surfaces WARNING On...

Page 3: ...iver Mounting screws Installation 1 Turn off power source 2 Locate T nut in channel on extrusion Line up either L or flat bracket holes with T nut holes Using a M5 x 5mm screw attached bracket to T nut Tighten until T nut rotates in channel L Bracket shown 3 Use 3 brackets for each 40 Stik module Use 2 brackets for each 20 Stik module 4 Use appropriate hardware to mount to final surface ...

Page 4: ...ODULES are used to form ASSEMBLIES ASSEMBLIES and or MODULES have a 12 cable with connector that can be plugged into one another to form long STRINGS of lights STRINGS can be as long as the chart shown See chart for maximum STRING length Contact LiteSheet for longer ASSEMBLY or STRING lengths Stik Module Stik Assembly String of lights ...

Page 5: ... to wire to a junction box on one end a middle MODULE or ASSEMBLY which will have a quick connector on both ends and an end MODULE or ASSEMBLY which will have a quick connector on one end and an end plate on the other end MODULES ASSEMBLIES AND STRINGS MUST NOT BE UNPLUGGED OR PLUGGED TOGETHER WHILE POWER IS APPLIED 2 Only the starter MODULE is connected to power On the starter MODULE or ASSEMBLY ...

Page 6: ...BSE2 BriteCor Damp Location Stik Installation Manual Page 6 of 6 For warranty information and technical support contact us at 434 446 1460 Find more great products at www litesheet com ...

Reviews: