Litecraft 2PiX.80 Mk2 User Manual Download Page 19

19

•  There are specific regulations like BGV C1 (old VBG 70) or 

country related regulations which need to attend during 
the installation. The installation has to be handled by skilled 
persons only!

•  Suspension device hast to be built and calculated in order to 

handle up to 10 times its specific load limit over a time of one 
hour without permanent or harmful deformation.

•  Installation has to be done with a separate, independent sus­

pension device like a safety chain. A second suspension device 
has to be built in order to assure that in case of error no part 
of an installation can fall off.  

•  Trepassing the danger zone below the installation during the 

assembling is prohibited.

•  Installer has to take care of all safety and machinery instal­

lations are approved by authorized persons before first opera­
tion or after changes before restarting.

•  Installer has to take care of all safety and machinery installa­

tions are approved by skilled persons at least once a year.

•  Installer has to take care of all safety and machinery installa­

tions are approved by authorized persons at least every four 
years during the acceptance inspection.

•  Spotlight should ideally installed outside peoples lounge area. 

ATTENTION!
Installation overhead needs a high level of experience. This 
includes (but is not just limited to) calculation and definition 
of load capacity, used installation material and regular safety 
inspections of used material and the fixture itself. Never try to 
do the installation by yourself if you are not qualified, instead 
you have to instruct a skilled installer. Inappropriate installa-
tions can cause injuries and/or damage of property.

•  Spotlight has to be installed outside areas where people can 

touch it.

•  Professional truss system or similar licensed suspension 

systems have to be used if the spotlight is used in suspension 
from ceiling or other constructions. Spotlights can never be 
installed freely suspended!

ATTENTION!
Spotlights can cause injuries when fall off. If you are not 
trained in questions of safety for the different kinds of installa-
tion do NOT install the spotlight!

•  Assure that the mounting surface can hold at least ten times 

the point load of the spotlight before installing the fixture.

 Installation

ATTENTION!
Assure the specified safety distances to flammable material.

•  Attach the spotlight with its yoke and the use of a suitable 

hook/clamp to your truss system. According to your installa­
tion also similar but approved suspension devices are possible. 
The therefor used opening has a diameter of about 12 mm.

•  When installing the spotlight overhead make sure to safe the 

fixture by a safety chain which is specified at least with a load 
limit of 12 times of the spotlights weight. Only safety chain 
with approved connective can be used. Attach the safety 
chain to its designated opening and attach it to the truss 
system or a similar and safe attachment point. Assure to close 
the fasteners as specified.

•  To adjust the angle of the fixture open the locking screw, set 

the fixure in its position and close it by hand.

Summary of Contents for 2PiX.80 Mk2

Page 1: ...Bedienungsanleitung User Manual measurements wide mm height mm measurements wide mm height mm...

Page 2: ......

Page 3: ...the instruction manual carefully before turn on the product for the first time Content Sicherheitshinweise 4 Bestimmungsgem e Verwendung 4 Montage 5 Elektrischer Anschluss 8 Reinigung und Wartung 8 B...

Page 4: ...nen Sie das Ger t immer vom Stromnetz wenn Sie es nicht verwenden oder wenn Sie es reinigen Ziehen Sie das Anschlusskabel nur mittels Netzstecker heraus W hrend der ersten Inbetriebnahme kann es zu le...

Page 5: ...rfers Versuchen Sie niemals die Installation selbst vorzunehmen wenn Sie nicht ber eine solche Qualifikation verf gen sondern beauftragen Sie einen professionellen Installateur Unsachgem e Installatio...

Page 6: ...wissern Sie sich das die Schrauben nach der Anpassung wieder fest angezogen sind WICHTIG Die seitlichen Verbindungselemente dienen ausschlie lich der Ausrichtung sprich der Verbindung von mehreren BPi...

Page 7: ...ial welches der BGV C1 entspricht WICHTIG Die seitlichen Verbindungselemente sowie die Verbindungsele mente oben und unten dienen ausschlie lich der Ausrichtung sprich der Verbindung von mehreren QPiX...

Page 8: ...25 m DPiX 1 Mk2 QPiX 144 Mk2 35 m Elektrischer Anschluss Reinigung und Wartung Der Installateur hat daf r Sorge zu tragen dass sicherheits technische und maschinentechnische Einrichtungen min destens...

Page 9: ...l Ausgang RJ 45 Netzwerk Eingang 1 RJ 45 Netzwerk Eingang 2 Taster Beschreibung Dr cken Sie die MENU Taste um in das Men zu gelangen Dr cken Sie die MENU Taste oder die UP DOWN Tasten um den gew nscht...

Page 10: ...et Universe 3 Standard Einstellung 2 Universe 4 Universe 4 0 15 Einstellung des ArtNet Universe 4 Standard Einstellung 3 Universe 5 Universe 5 0 15 Einstellung des ArtNet Universe 5 Standard Einstellu...

Page 11: ...enlose Helligkeit Rot K239 Dimmer Gr n 000 255 stufenlose Helligkeit Gr n K240 Dimmer Blau 000 255 stufenlose Helligkeit Blau LPiX 40 Mk2 03 0 0 241 K241 Dimmer Rot 000 255 stufenlose Helligkeit Rot K...

Page 12: ...241 siehe oben LPiX 40 Mk2 12 0 2 362 siehe oben LPiX 40 Mk2 13 0 3 1 siehe oben LPiX 40 Mk2 14 0 3 121 siehe oben LPiX 40 Mk2 15 0 3 241 siehe oben LPiX 40 Mk2 16 0 3 362 siehe oben LPiX 40 Mk2 17 0...

Page 13: ...Dimmer Blau 000 255 stufenlose Helligkeit Blau K478 Dimmer Rot 000 255 stufenlose Helligkeit Rot K479 Dimmer Gr n 000 255 stufenlose Helligkeit Gr n K480 Dimmer Blau 000 255 stufenlose Helligkeit Blau...

Page 14: ...elligkeit Rot K239 Dimmer Gr n 000 255 stufenlose Helligkeit Gr n K240 Dimmer Blau 000 255 stufenlose Helligkeit Blau 2PiX 80 Mk2 03 0 0 241 K241 Dimmer Rot 000 255 stufenlose Helligkeit Rot K242 Dimm...

Page 15: ...144 Mk2 03 0 2 1 siehe oben QPiX 144 Mk2 04 0 3 1 siehe oben QPiX 144 Mk2 05 0 4 1 siehe oben QPiX 144 Mk2 06 0 5 1 siehe oben QPiX 144 Mk2 ArtNet Patching SubNet Universe DMX Adresse Funktion 2PiX 80...

Page 16: ...en 48 3 x 5 4 x 15 0 cm Gewicht 3 1 kg Gewicht 2 2 kg Absicherung T5 0 A 250 V Pixel Pitch 25 mm Max Anzahl 24 Geh use Schutzklasse IP 20 Geh use Schutzklasse IP 20 Technische Spezifikation LPiX 40 Mk...

Page 17: ...mm mm Abmessungen 115 5 x 2 8 cm Abmessungen 30 0 x 30 0 x 11 8 cm Gewicht 0 33 kg Gewicht 2 6 kg Pixel Pitch 25 mm Pixel Pitch 25 mm Max Anzahl 16 Max Anzahl 6 Geh use Schutzklasse IP 20 Geh use Sch...

Page 18: ...he voltage specified in this manual Disconnect the unit from the AC mains when it is not in use or when cleaning it Disconnect the connection only by pulling the cable plug Using the fixture for the f...

Page 19: ...and the fixture itself Never try to do the installation by yourself if you are not qualified instead you have to instruct a skilled installer Inappropriate installa tions can cause injuries and or dam...

Page 20: ...e of 6 5 cm to fit to the surroundings Make sure that you tighten the screws after you adjust the yoke NOTE The connection elements mounted at the sides are only used for alignment means the connectio...

Page 21: ...ers as specified 2PiX 80 Mk2 2PiX 80 Mk2 can be mount as single stick due to one of the both M10 treads on its head Only use suitable hooks clamps approved by the BGV C1 for this kind of installation...

Page 22: ...k2 25 m DPiX 1 Mk2 2PiX 80 Mk2 25 m DPiX 1 Mk2 QPiX 144 Mk2 35 m Electrical Connection Cleaning and Maintenance Installer has to take care of all safety and machinery installati ons are approved by sk...

Page 23: ...utput RJ 45 Network Input 1 RJ 45 Network Input 2 1 2 3 4 5 6 7 8 6 1 4 5 2 3 9 10 11 7 8 9 10 11 Button description Press the MENU button to get access to the menu Press the MENU button or UP DOWN bu...

Page 24: ...erse 3 Universe 3 0 15 setting of artnet universe 3 default setting 2 Universe 4 Universe 4 0 15 setting of artnet universe 4 default setting 3 Universe 5 Universe 5 0 15 setting of artnet universe 5...

Page 25: ...less brightness red ch239 dimmer green 000 255 steppless brightness green ch240 dimmer blue 000 255 steppless brightness blue LPiX 40 Mk2 03 0 0 241 ch241 dimmer red 000 255 steppless brightness red c...

Page 26: ...11 0 2 241 as above LPiX 40 Mk2 12 0 2 362 as above LPiX 40 Mk2 13 0 3 1 as above LPiX 40 Mk2 14 0 3 121 as above LPiX 40 Mk2 15 0 3 241 as above LPiX 40 Mk2 16 0 3 362 as above LPiX 40 Mk2 17 0 4 1 a...

Page 27: ...n ch3 dimmer blue 000 255 steppless brightness blue ch478 dimmer red 000 255 steppless brightness red ch479 dimmer green 000 255 steppless brightness green ch480 dimmer blue 000 255 steppless brightne...

Page 28: ...ghtness red ch239 dimmer green 000 255 steppless brightness green ch240 dimmer blue 000 255 steppless brightness blue 2PiX 80 Mk2 03 0 0 241 ch241 dimmer red 000 255 steppless brightness red ch242 dim...

Page 29: ...1 as above QPiX 144 Mk2 03 0 2 1 as above QPiX 144 Mk2 04 0 3 1 as above QPiX 144 Mk2 05 0 4 1 as above QPiX 144 Mk2 06 0 5 1 as above QPiX 144 Mk2 ArtNet Patching subnet universe DMX adress function...

Page 30: ...easurements 48 3 x 5 4 x 15 0 cm weight 3 1 kg weight 2 2 kg fuse T5 0 A 250 V pixel pitch 25 mm max quantity 24 ip rating IP 20 ip rating IP 20 Technical Specification LPiX 40 Mk2 DPiX 1 Mk2 artnet c...

Page 31: ...15 5 x 2 8 cm weight 0 33 kg pixel pitch 25 mm max quantity 16 ip rating IP 20 2PiX 80 Mk2 artnet channels 432 measurements 30 0 x 30 0 x 11 8 cm weight 2 6 kg pixel pitch 25 mm max quantity 6 ip rati...