EDX-1210/EDX-620 [EUM-D] 14
2-3 DMX-512 Start Address Setting
Although we would recommend applying RS- 485 rather than DMX-512 on EDX systems,
EDX-1210 is still compatible with DMX-512. Note that DMX-512 controllers have higher priority
than other EDX controllers.
STEP-1: Press
【
FNC
】
to enter the menu. Select "
F1: DMX_ADR"
, and LCD shows:
STEP-2: Press
【
】
or
【
】
to set DMX-512 starting address.
STEP-3: Press
【
ENTER
】
to save the setting or press
【
FNC
】
to exit.
1. In DMX mode, there are 512 channels available for start channel address setting.
Example: (Each EDX-1210 can output 12 channels continuously.)
DMX Start Address: 001, its DMX signal can output from channel 1 to channel 12 continuously.
DMX Start Address: 007, its DMX signal can output from channel 7 to channel 18 continuously.
2. Duplicated DMX address is available. That is, two or more EDX-1210s can be set to the
same DMX address.
2-4 ID Number Setting
Each EDX series device must have an ID number (The default setting is 001.). When one
device’s working alone, there is no need to adjust the ID number, but when several devices’
working together, each device must have a different ID number.
STEP-1: Press
【
FNC
】
to enter the menu. Select "
F2: ID SET "
, and LCD shows:
STEP-2: Press
【
】
or
【
】
to set the ID number.
STEP-3: Press
【
ENTER
】
to save the setting or press
【
FNC
】
to exit.
Summary of Contents for EDX-1210
Page 1: ...EDX 1210 EDX 620 EUM D 1 User Manual EDX 1210 EDX 620 12 6 Channel Dimmer Pack...
Page 7: ...EDX 1210 EDX 620 EUM D 7 1 5 Output Terminals EDX 1210 EDX 620 EDX 1210...
Page 8: ...EDX 1210 EDX 620 EUM D 8 EDX 620...
Page 9: ...EDX 1210 EDX 620 EUM D 9 1 6 Analog 0 10V DC Output Terminals EDX 1210 EDX 620 EDX 1210...
Page 10: ...EDX 1210 EDX 620 EUM D 10 EDX 620...