5
2-1-2 Purpose of Zone Setting
T
he ECP-110T can control up to 8 zones at the same time. Before using it, be confirm
the zones controlled by each panel.
ECP-110T has 2 setting modes: panel setting and DIP setting.
DIP.10 (OFF): panel setting zone
(
2-1-3
)
;
DIP.10 (ON): DIP setting zone (2-1-4).
ECP-110T has 2 control modes: single-zone mode or multi-zone mode.
DIP.9 (OFF): single-zone mode;
DIP.9 (ON): multi-zone mode.
2-1-3 Zone Setting
1.
DIP 10(OFF) and hold
【
ZONE
】
, and then hold
【
4
】
for 5 seconds till
【
▼
】
or
【
▲
】
is flickering.
2. Keep holding
【
ZONE
】
and release
【
4
】
.
3. By default, the backlight of
【
1
】
is in red, which means the zone number is 1 no matter in single or
multi zone mode.
Zone setting Code
Single / multi-zone Code
Panel/DIP Code