Appendix: Binary Code Principal

 

ZONE   

 

8 bit DIP

   

ZONE   

 

8 bit DIP

   

ZONE   

 

8 bit DIP

   

 

 

 

12345678 

   

 

 

 

12345678 

   

 

 

 

12345678 

   

 

   

  10000000     

 

   

  01000000     

 

   

  11000000     

 

   

  00100000     

 

   

  10100000     

 

   

  01100000     

 

   

  11100000     

 

   

  00010000     

 

   

  10010000     

 

10 

   

  01010000     

 

11 

   

  11010000     

 

12 

   

  00110000     

 

13 

   

  10110000     

 

14 

   

  01110000     

 

15 

   

  11110000     

 

16 

   

  00001000     

 

17 

   

  10001000     

 

18 

   

  01001000     

 

19 

   

  11001000     

 

20 

   

  00101000     

 

21 

   

  10101000     

 

22 

   

  01101000     

 

23 

   

  11010000     

 

24 

   

  00011000     

 

25 

   

  10011000     

 

26 

   

  01011000     

 

27 

   

  11011000     

 

28 

   

  00111000     

 

29 

   

  10111000     

 

30 

   

  01111000     

 

31 

   

  11111000     

 

32 

   

  00000100     

 

33 

   

  10000100     

 

34 

   

  01000100     

 

35 

   

  11000100     

 

36 

   

  00100100     

 

37 

   

  10100100     

 

38 

   

  01100100     

 

39 

   

  11100100     

 

40 

   

  00010100     

 

41 

   

  10010100     

 

42 

   

  01010100     

 

43 

   

  11010100     

 

44 

   

  00110100     

 

45 

   

  10110100     

 

46 

   

  01110100     

 

47 

   

  11110100     

 

48 

   

  00001100     

 

49 

   

  10001100     

 

50 

   

  01001100     

 

51 

   

  11001100     

 

52 

   

  00101100     

 

53 

   

  10101100     

 

54 

   

  01101100     

 

55 

   

  11101100     

 

56 

   

  00011100     

 

57 

   

  10011100     

 

58 

   

  01011100     

 

59 

   

  10011100     

 

60 

   

  00111100     

 

61 

   

  10111100     

 

…   

 

 

…   

 

 

255 

      11111111     

0 = DIP/OFF; 1= DIP/ON. 

 

 

 

Summary of Contents for ECP-110T

Page 1: ...ISO 9001 CERTIFIED www liteputer com tw Lite Puter ECP 110T EUM B ECP 110T Control Panel USER MANUAL Lite Puter Enterprise Co Ltd Website www liteputer com tw E mail sales liteputer com tw...

Page 2: ...4 HOW TO OPEN FRONT COVER 3 1 5 WIRING 3 2 OPERATIONS 4 2 1 ZONE SETTING 4 2 1 1 About EDX System 4 2 1 2 Purpose of Zone Setting 5 2 1 3 Zone Setting 5 2 1 4 Zone Setting of DIP 8 2 2 SCENE RECALL 8...

Page 3: ...ol up to 8 zones at the same time 2 Recall 6 scenes 3 Fine adjust the dimming level 4 256 level dimming resolutions 5 Key Lock unlock function 6 IR receiver 7 Two dry contact inputs 1 2 Specifications...

Page 4: ...ISO 9001 CERTIFIED www liteputer com tw Lite Puter ECP 110T EUM B 2 Rear side 1 Scene 1 6 scene OFF 2 Down Up 3 ZONE zone 4 DIP switch...

Page 5: ...ISO 9001 CERTIFIED www liteputer com tw Lite Puter ECP 110T EUM B 3 1 4 How to Open Front Cover Slotted Screwdriver 1 5 Wiring...

Page 6: ...al lighting applications EDX dimmers or devices are able to store scenes in themselves Each EDX device or ECP panel can be assigned a zone number The scenes stored in EDX devices can be recalled by EC...

Page 7: ...OFF panel setting zone 2 1 3 DIP 10 ON DIP setting zone 2 1 4 ECP 110T has 2 control modes single zone mode or multi zone mode DIP 9 OFF single zone mode DIP 9 ON multi zone mode 2 1 3 Zone Setting 1...

Page 8: ...tructions Single zone mode DIP9 OFF Each button presents 1 1 2 2 3 4 4 8 5 16 6 32 64 128 For example to set zone number as 3 in single zone mode Press 1 2 to make their backlight to red 1 1 2 2 1 2 3...

Page 9: ...ne 1 2 zone 2 3 zone 3 4 zone 4 5 zone 5 6 zone 6 zone 7 zone 8 For example to set zone number to 1 and 2 to control zone 1 and 2 at the same time Press 1 and 2 to make their backlight to red For exam...

Page 10: ...call Press 1 6 to recall corresponding scenes For example press 1 to recall the SC1 and the backlighting of the button will be in red Press 1 6 once the scenes will be recalled with fade in effect Qui...

Page 11: ...lock Lock Unlock 2 5 IR Remote Control ECP 110T can receive infrared signal from remote controller IR 0501 to recall the scenes and adjust dimming level 1 Hold ZONE and then hold 2 for 5 seconds till...

Page 12: ...ISO 9001 CERTIFIED www liteputer com tw Lite Puter ECP 110T EUM B 10 2 6 Dry Contact Inputs The scene 1 will be recalled by actuating input 1 The scene 2 will be recalled by actuating input 2...

Page 13: ...000 18 01001000 19 11001000 20 00101000 21 10101000 22 01101000 23 11010000 24 00011000 25 10011000 26 01011000 27 11011000 28 00111000 29 10111000 30 01111000 31 11111000 32 00000100 33 10000100 34 0...

Page 14: ...arranty does not cover a Any fault caused by false usage imprudence collision inadequate installation or adjustment insufficient ventilation or improper repairs b Force majeure factors flooding earthq...

Page 15: ...No 189 Gangqian Rd Neihu Dist Taipei City 11494 Taiwan Tel 886 2 27998099 Fax 886 2 27993828 Website www liteputer com tw E mail sales liteputer com tw Shanghai Factory Lite Puter Technology Shanghai...

Reviews: