LITE-CHECK INSPECTOR 920
Page 24 of 36
message for a few moments, and then automatically
exit the test. The PLC is read through the auxiliary
circuit and will have no faults.
Next the tester will search for the PLC Signal and will
attempt to determine the ECU Manufacturer. This
process may take up to a minute to complete.
Once the PLC is detected, the ECU will be identified;
the ECU manufacturer will display along with other
information including any active faults present in the
system:
NOTE
: Each star indicates a stage in the ECU
information retrieval. If the tester is unable to complete
identification note the number of stars and contact LITE-CHECK customer support.
Main Menu
Pressing the
SELECT
button displays the
ABS
menu. Use the
UP
and
DOWN
buttons
to navigate the menu. The
cursor
‐
>
on the display will
move up and down, indicating which option selected. Press the
SELECT
button to
choose a menu option.
Move the cursor –> to the bottom of the digital display and pressing the
DOWN
button
once more will display additional menu options.
Viewing Active Faults
View an active fault by using the DOWN button to the
“
VIEW ACTIVE FAULT
” option and pressing
SELECT
.
The digital display will show the active faults.
Pressing the
DOWN
button will display the first active
fault. In this case, an “Open/Short Circuit” is indicated.
Press the
DOWN
button again to display the next active
fault. Press the
UP
button to return to the previous fault.
‐
>ECU VOLTAGE
MFG/CONFIGURATION
SERIAL NUMBER
SPECIAL FUNCTIONS
VIEW ACTIVE FAULTS
NUMBER FOUND (2)
Press up down keys
to see faults.
ACTIVE FAULT No. 1
FAULT CODE:02 CT:2
S1B RED SENSOR
OPEN/SHORT CIRCUIT