70/92
11.9.
Troubleshooting
The internal combustion engine must be turned off before starting any maintenance or repair work.
Secure against accidental restart.
Maintenance and service work may only be carried out by qualified technical personnel.
NOTICE
In case of cutting problems, check the following points:
Saw blade blunt or defective?
Too little water to cool the saw blade?
Correct saw blade selected?
Full capacity and speed of motor?
Error
Possible cause
Remedy
Poor cutting performance
Saw blade is blunt
Replace saw blade
Engine does not have the full output
See operating instructions of the internal
combustion engine
Wrong saw blade speed
Check saw blade speed
Wrong saw blade direction of rotation
Check saw blade direction of rotation
Too little cooling water
Clean the water filter or
rinse water supply system at a
max. pressure of 5 bar
Floor saw does not start
Fuel tank empty
DEF tank empty
Refuel
Check display - Contact Service
Fuel filter dirty
Disassemble and clean the fuel filter
Battery voltage too low
Check battery voltage and charge, if necessary
Floor saw goes off after 50 s
Seat switch defective
Replace switch
11.10.
Support and training
If you have a problem with the machine, need spare parts, accessories or would
like to receive training, Do not hesitate to contact your support distributor or our
service.