This function displays the register/meter number. This function is only available if the register is set for litres.
1.
Press the TOTAL
button five times in five seconds.
2.
Press the MENU
button until “MeNoXXXX” is displayed on the display, where XXXX is the meter
number nominated.
Note: If no button is pressed for five (5) seconds, the DFV will exit and return to standby mode.
3.6
Displaying the Accumulative Total
To display the accumulative total, press the TOTAL
button. The register will show whole litres (or gallons)
volume. This value continually changes during delivery and is displayed for 5 seconds.
4.
PRINTING A TICKET
4.1
Printing a Delivery Ticket
1.
Ensure a blank ticket is inserted into the printer or a paper roll is present.
2.
Press the RESET
button when delivery is complete. The “print dt” message is shown on the upper
display while printing. When printing is completed, the meter returns back to standby mode and the
display is reset back to “0.0”.
4.2
Printing a Setup Report Ticket
Setup report tickets display various settings of the register.
1.
Ensure a blank ticket is inserted into the printer or a paper roll is present.
2.
Press the TOTAL
button five times in five seconds.
3.
Press the MENU
button until “REPORT?N” is displayed on the display.
Note: If no button is pressed for five (5) seconds, the DFV will exit and return to stand by mode.
4.
Press the TOTAL
button to change the display to “REPORT?Y”
5.
Press the START/STOP
button to start printing. The “print report” message is shown on the display
while printing. When printing is completed, the meter returns back to standby mode.
Pressing TOTAL
immediately followed by RESET
while in standby mode will print a management
ticket. This will reset the power interrupts and the delivery number to zero, but will not reset the register to
zero.
5.