Installation
Mounting the LCR 600
Mounting Bolt Pattern
The LectroCount LCR 600 base casting contains eight bolt holes in an industry standard bolt pattern. The
holes are ½" deep and take ¼"-20 screws.
If the installation necessitates that you fabricate a bracket, refer to the drawing to the right.
LC Meters
Remove Existing Registration Equipment
Follow these steps:
1. Depressurize the meter completely. See the Warnings in
.
2. Remove the four bolts on the bottom that fasten the register to the meter.
3. Remove the adjuster from the meter.
4. If the meter has a Temperature Volume Compensator (TVC), remove it as well.
29