Rev: 05.24.2016
Page 8
Slim Rack Slide-out Manual
Troubleshooting
This control has the ability to detect and display several faults. When a fault is detected, the room movement
may stop and 2 different LEDs on the control box will flash in a pattern.
•
The Fault Code LED (Fig. 9) on the rocker switch will flash RED a number of times corresponding to
the number of red flashes on the control box (Fig. 9). Refer to the troubleshooting chart below to best
determine what caused the fault.
•
The Motor LED (Fig. 9) on the control box will flash GREEN a number of times corresponding to which
motor had the associated fault. For example: 2 GREEN flashes and 4 RED flashes means there is a motor
fault on motor 2.
NOTE:
For major faults, the control will automatically enter "Emergency Jog" mode when motor movement
is not detected by the control box in either direction during room actuation. When in "Emergency
Jog" mode, the control will jog both motors in the direction the rocker switch is pressed (IN or OUT).
The rocker switch may need to be pressed multiple times to fully retract or extend the room. Take
the unit to an OEM authorized dealer for service.
NOTE:
The control box will return to normal operation mode after 5 minutes of inactivity or by cycling
power to the control box.
Fault Code Flashes
Fault
Type
Description
Why?
What Should Be Done?
Green Flash Red Flash
1
1
Minor
Park Brake
Not Set
Park Brake not set (if
applicable).
Ground signal lost at
park brake receptacle
at control box.
Set parking brake (if applicable).
Check for continuity to ground
on wire plugged into park brake
receptacle at control box.
1
2
Minor
Low Voltage
Incoming voltage
to control is below
12.0 VDC. The room
will NOT move if the
voltage is 10.5 VDC or
below.
Start vehicle, generator, or ensure
coach is plugged into shore power.
Check 2-pin power connector at
control box at BATT + and GND.
Consult manufacturer of unit
charging system for troubleshooting
assistance.
1
4
Major
Motor 1
Fault
Bad wire connection
Bad motor
Refer to TIP Sheet 82-S0533 for
troubleshooting.
2
4
Major
Motor 2
Fault
Bad wire connection
Bad motor
1
6
Minor
High
Voltage
Supply voltage to
control box is 17 VDC
or greater.
Consult manufacturer of unit
charging system for troubleshooting
assistance.
Fig. 9
Green
Red