WARNING

FAILURE TO ACT IN ACCORDANCE WITH THE FOLLOWING MAY

RESULT IN SERIOUS PERSONAL INJURY OR DEATH.

The 

Lippert Hydraulic Slideout System

 is intended for the sole

purpose of extending and retracting the slideout room.  Its

function should not be used for any other purpose or reason than

to actuate the slideout room.  To use the system for any reason

other than what it is designed for may result in damage to the

coach and/or cause serious injury or even death.

Before actuating the system, please keep these things in mind:

1.  Parking locations should be clear of obstructions that may

cause damage when the slideout room is actuated.

2.  Be sure all persons are clear of the coach prior to the

slideout room actuation.

3.  Keep hands and other body parts away from slideout

mechanisms during actuation.  Severe injury or death may

result.

4.  To optimize slideout actuation, park coach on solid and level

ground.

DESCRIPTION

The 

Lippert Hydraulic Slideout System

 is a rack & pinion guide system, utilizing a

hydraulic actuator to move the room assembly. The power unite drives the
cylinder rod in a forward and backward motion to drive the slide room in and out.
The 

Lippert Hydraulic Slideout System

 is designed to operate as a negative

ground system.

3

PRIOR TO OPERATION

Prior to operating the 

Lippert Hydraulic Slideout System

, follow these guidelines:

1.  Coach should be parked on the most level surface available.
2.  Leveling or stabilizing system should be actuated to ensure coach will not
     move during operation of Bed Lift System.
3.  Be sure battery is fully charged.
4.  Be sure to keep all persons and pets clear of Bed Lift System during
     operation.

Summary of Contents for HYDRAULIC SLIDEOUT SYSTEM

Page 1: ...HYDRAULIC SLIDEOUT SYSTEM OPERATION AND SERVICE MANUAL...

Page 2: ...PERATION Warning Extending Slideout Room Retracting Slideout Room Auxiliary Operation SERVICE Filling Procedures Adjustment Instructions Syncronizing System Replacing Actuator Troubleshooting Wiring D...

Page 3: ...on 3 Keep hands and other body parts away from slideout mechanisms during actuation Severe injury or death may result 4 To optimize slideout actuation park coach on solid and level ground DESCRIPTION...

Page 4: ...ctric actuator motor for corrosion and loose or damaged terminals Check motor leads under the trailer chassis Since these connections are subject to damage from road debris be sure they are in good co...

Page 5: ...d 4 Press and hold the IN OUT switch Fig 1B in the OUT position until the room is fully extended and stops moving 5 Release the switch which will lock the room into position NOTE If the slideout switc...

Page 6: ...e i e cordless drill or screwdriver or ratchet wrench AUXILIARY OPERATION The Lippert Hydro Sync Slideout System can be run with auxiliary power devices like electric drills ratchet wrenches or cordle...

Page 7: ...etic blend works best such as Dexron III or Mercon 5 For best operation fill system within of the top when all slideouts are completely retracted The see through reservoir makes it easy to check oil l...

Page 8: ...ustment 1 Loosen 2 carriage bolts A on each bracket located at the end of each guide tube 2 Loosen jam nut 3 For vertical adjustment turn vertical adjustment bolt B up or down to locate room height On...

Page 9: ...ket Make sure Jam Nut 2 is adjusted for FREE TRAVEL see above Secure assembly by tightening Jam Nut 1against Jam Nut 2 This will change the location of your seal going to the in position Adjusting roo...

Page 10: ...ATOR Fig 10 10 The Lippert Electric Slideout System room travel both sides of the room traveling the same distance can be adjusted with specially designed synchronizing bracket mounted on the passive...

Page 11: ...m POWER UNIT RUNS ROOM DOES NOT MOVE Restrictions both inside and outside of unit Check for and clear restriction POWER UNIT RUNS ROOM MOVES SLOWLY Low battery poor ground extremely low Charge battery...

Page 12: ...om 5 Continue to run the room in and watch for fluid flow from hose port E Fluid flow greater than a few drops will indicate internal cylinder leaking bypassing of piston seal If there is no fluid flo...

Page 13: ...ay Yellow Red Hot Green BATTERY No wires connected to this side of switch CHANGE OF POLARITY REVERSES MOTOR MANIFOLD RESERVOIR RV MANUFACTURER SUPPLIED BREAKER CUSTOMER S CHOICE CUSTOMER TO INSTALL AP...

Reviews: