background image

TROUBLESHOOTING CHART

The following troubleshooting chart outlines some common problems, their causes and possible
corrective actions.  When reference is made to a “Power Unit,” the term includes the motor and
the actuator as a complete unit.  All Power Units are shipped from the factory with a serial number
and date code, which should be given to the service technician when asking for assistance.

11

ROOM DOESN’T MOVE WHEN SWITCH IS PRESSED

PROBABLE CAUSE

CORRECTIVE ACTION

Restrictions both inside and outside of unit

Check for and clear restriction

Low battery voltage, blown fuse, defective wiring

                 Check battery.  Charge battery or add auxiliary
                 power source. Check battery terminals, and all
       other wiring.  Look for loose or corroded connections

Power Unit not functioning

  See “Power Unit Troubleshooting” page 20

            Hydraulic Slideout Manual online at www.lci1.com

POWER UNIT RUNS, ROOM DOES NOT MOVE

Restrictions both inside and outside of unit

Check for and clear restriction

POWER UNIT RUNS, ROOM MOVES SLOWLY

Low battery, poor ground, extremely low

                             Charge battery, and check ground wire

outdoor temperature.

Leaking cylinder

    See “Checking for Bad Cylinder” page 12

ROOM DRIFTS IN BOTH IN & OUT POSITIONS

Check for leaks in the hydraulic system

   Tighten fittings

Air in system

 After checking all connections, cycle pump
                               several times in and out

IN THE CLOSED POSITION, ROOM DRIFTS OUT

Leaking cylinder seal

    See “Checking for Bad Cylinder” page 12

Fluid bypassing cylinder piston

    See “Checking for Bad Cylinder” page 12

Hose from pump is leaking

Tighten fitting or replace hose

Air in system

 After checking all connections, cycle pump
                               several times in and out

Loose mounting bolts

           Tighten mounting bolts

IN THE OPEN POSITION, ROOM DRIFTS IN

Hose from pump is leaking

Tighten fitting or replace hose

Leaking cylinder seal

    See “Checking for Bad Cylinder” page 12

Fluid bypassing cylinder piston

    See “Checking for Bad Cylinder” page 12

Summary of Contents for HYDRAULIC SLIDEOUT SYSTEM

Page 1: ...HYDRAULIC SLIDEOUT SYSTEM OPERATION AND SERVICE MANUAL...

Page 2: ...PERATION Warning Extending Slideout Room Retracting Slideout Room Auxiliary Operation SERVICE Filling Procedures Adjustment Instructions Syncronizing System Replacing Actuator Troubleshooting Wiring D...

Page 3: ...on 3 Keep hands and other body parts away from slideout mechanisms during actuation Severe injury or death may result 4 To optimize slideout actuation park coach on solid and level ground DESCRIPTION...

Page 4: ...ctric actuator motor for corrosion and loose or damaged terminals Check motor leads under the trailer chassis Since these connections are subject to damage from road debris be sure they are in good co...

Page 5: ...d 4 Press and hold the IN OUT switch Fig 1B in the OUT position until the room is fully extended and stops moving 5 Release the switch which will lock the room into position NOTE If the slideout switc...

Page 6: ...e i e cordless drill or screwdriver or ratchet wrench AUXILIARY OPERATION The Lippert Hydro Sync Slideout System can be run with auxiliary power devices like electric drills ratchet wrenches or cordle...

Page 7: ...etic blend works best such as Dexron III or Mercon 5 For best operation fill system within of the top when all slideouts are completely retracted The see through reservoir makes it easy to check oil l...

Page 8: ...ustment 1 Loosen 2 carriage bolts A on each bracket located at the end of each guide tube 2 Loosen jam nut 3 For vertical adjustment turn vertical adjustment bolt B up or down to locate room height On...

Page 9: ...ket Make sure Jam Nut 2 is adjusted for FREE TRAVEL see above Secure assembly by tightening Jam Nut 1against Jam Nut 2 This will change the location of your seal going to the in position Adjusting roo...

Page 10: ...ATOR Fig 10 10 The Lippert Electric Slideout System room travel both sides of the room traveling the same distance can be adjusted with specially designed synchronizing bracket mounted on the passive...

Page 11: ...m POWER UNIT RUNS ROOM DOES NOT MOVE Restrictions both inside and outside of unit Check for and clear restriction POWER UNIT RUNS ROOM MOVES SLOWLY Low battery poor ground extremely low Charge battery...

Page 12: ...om 5 Continue to run the room in and watch for fluid flow from hose port E Fluid flow greater than a few drops will indicate internal cylinder leaking bypassing of piston seal If there is no fluid flo...

Page 13: ...ay Yellow Red Hot Green BATTERY No wires connected to this side of switch CHANGE OF POLARITY REVERSES MOTOR MANIFOLD RESERVOIR RV MANUFACTURER SUPPLIED BREAKER CUSTOMER S CHOICE CUSTOMER TO INSTALL AP...