Operating manual LL12 14/18 Version 1.6 (01/2017)
c) The platform hood is to be raised and secured against falling down by means of
the insertable arms.
d) The bolted connection of the front cladding must be undone using the hexagonal
wrench (provided in the envelope) and the cladding removed.
d) The brake venting lever is to be pressed upwards or downwards whilst at the
same time turning the hand wheel on the end of the motor shaft (
see illustration
below
).
In doing so, the direction of travel should always be towards the lower station (less
energy expenditure when turning the hand wheel). The respective direction of
rotation is indicated directly on the hand wheel.
Note: If the cause of the standstill is not clear, it should be assumed that the safety
arrester has been triggered and that its safety switch has led to the lift switching off.
The safety arrester may only be reset by technical personnel.
In this case,
proceeded as described in a) to e) above, but first turn the hand wheel in the UP
direction (until the lift has moved approx. 5 cm along the rail), after which the hand
wheel can be turned in the DOWN direction.
Prop
Brake venting lever