12. Technical data fan unit
The fan units require a maximum oil quantity of 16 l/min at max. 150
bar. The crossflow fan are driven by the hydraulics of the harvester.
The tractor should be equipped with an oil flow regulator so that the
air volume can be regulated.
Oil flow regulator is available at LIPCO.
Nominal volumetric flow/cross flow fan:
This is measured in the free air flow at 0.6 m distance from air flow
outlet of cross flow fan:
Fan length - (m)
RPM
Air speed
(m/sec.)
Nominal volumetric
flow (m³)
2,5
800
6
2,5
1000
8
2,5
1200
10
2,5
1400
12
3,0
800
3,0
1000
3,0
1200
3,0
1400