![LION EXPLO TRAINER User Manual Download Page 7](http://html1.mh-extra.com/html/lion/explo-trainer/explo-trainer_user-manual_1926184007.webp)
Explo Trainer
User’s Manual
Version 1.1 | 18/06/19
Page 6
A normal full charging cycle will take approximately 4 hours. The charging circuit continuously monitors
the battery status and switches to trickle charge when the battery is fully charged.
Generally speaking, it is sufficient to charge up all the transmitters at the same time as the Instructor Unit
and Student Unit, to always have a working set. If the range of a transmitter becomes significantly
weaker before the batteries of the Instructor Unit or Student Unit are empty, the battery power level is
very low and must be charged up before continuing with the training.
The transmitter is not equipped with a dedicated battery indicator. However, when the battery is empty,
the power indicator will light continuously. The transmitter will not operate reliable anymore, the battery
needs to be recharged.
Student Unit
Operation
The Student Unit is operated by means of a single button, controlling all the functions of the gas meter.It
features optical and auditory alarms and has the option of connecting a measuring probe.
Connectors, controls and indicators of the Student
(1) Measuring sensor
(2) Measuring probe connector
(3) Optical alarm & charger indicator (front)
(4) Optical alarm (top)
(5) LCD Display
(6) Power button
(7) Charger connector
Switching on
-
Press the power button (6) briefly.
The device will switch itself on and give a short optical signal (3,4) and
a short beep. The device will start up and shortly show the LION
logo on the display (5) (figure 3.3).
The device will then automatically switch to measuring mode.
Four measurements are shown:
•
Lower Explosion Limit (%LEL)
•
Oxygen (O
2
)
•
Hydrogen Sulfide (H
2
S)
•
Carbon Monoxide (CO)
The wireless communication channel and internal
battery level are shown on the right.
Figure 3.3: Controls of the Student Unit
Figure 3.4: Measuring mode display