background image

     

     

44

45

Production Guidelines

The module is housed in a hybrid SMD package that supports hand and 
automated assembly techniques. Since the modules contain discrete 
components internally, the assembly procedures are critical to ensuring 
the reliable function of the modules. The following procedures should be 
reviewed with and practiced by all assembly personnel.

Hand Assembly

Pads located on the bottom 
of the module are the primary 
mounting surface (Figure 38). 
Since these pads are inaccessible 
during mounting, castellations 
that run up the side of the module 
have been provided to facilitate 
solder wicking to the module’s 
underside. This allows for very 
quick hand soldering for prototyping and small volume production.  If the 
recommended pad guidelines have been followed, the pads will protrude 
slightly past the edge of the module. Use a fine soldering tip to heat the 
board pad and the castellation, then introduce solder to the pad at the 
module’s edge. The solder will wick underneath the module, providing 
reliable attachment. Tack one module corner first and then work around the 
device, taking care not to exceed the times in Figure 39.

Automated Assembly

For high-volume assembly, the modules are generally auto-placed. 
The modules have been designed to maintain compatibility with reflow 
processing techniques; however, due to their hybrid nature, certain aspects 
of the assembly process are far more critical than for other component 
types. Following are brief discussions of the three primary areas where 
caution must be observed.

Castellations

PCB Pads

Soldering Iron
Tip

Solder

Figure 38: Soldering Technique

Warning: 

Pay attention to the absolute maximum solder times.

Figure 39: Absolute Maximum Solder Times

Absolute Maximum Solder Times

Hand Solder Temperature: +427ºC for 10 seconds for lead-free alloys

Reflow Oven: +255ºC max (see Figure 40)

Reflow Temperature Profile

The single most critical stage in the automated assembly process is the 
reflow stage. The reflow profile in Figure 40 should not be exceeded 
because excessive temperatures or transport times during reflow will 
irreparably damage the modules. Assembly personnel need to pay careful 
attention to the oven’s profile to ensure that it meets the requirements 
necessary to successfully reflow all components while still remaining 
within the limits mandated by the modules. The figure below shows the 
recommended reflow oven profile for the modules.

Shock During Reflow Transport

Since some internal module components may reflow along with the 
components placed on the board being assembled, it is imperative that 
the modules not be subjected to shock or vibration during the time solder 
is liquid. Should a shock be applied, some internal components could be 
lifted from their pads, causing the module to not function properly.

Washability

The modules are wash-resistant, but are not hermetically sealed. Linx 
recommends wash-free manufacturing; however, the modules can be 
subjected to a wash cycle provided that a drying time is allowed prior 
to applying electrical power to the modules. The drying time should be 
sufficient to allow any moisture that may have migrated into the module 
to evaporate, thus eliminating the potential for shorting damage during 
power-up or testing.  If the wash contains contaminants, the performance 
may be adversely affected, even after drying.

125°C

185°C

217°C

255°C

235°C

60

120

30

150

180

210

240

270

300

330

360

0

90

50

100

150

200

250

300

Recommended RoHS Profile
Max RoHS Profile

Recommended Non-RoHS Profile

180°C

Temperature 

(

o

C)

Time (Seconds)

Figure 40: Maximum Reflow Temperature Profile

Summary of Contents for EVAL-900-TT

Page 1: ...TT Series Remote Control and Sensor Transceiver Data Guide...

Page 2: ...RF products must understand and must use all appropriate safety procedures in connection with the devices including without limitation using appropriate safety procedures to prevent inadvertent trigg...

Page 3: ...nfiguration is provided by a UART interface however no programming is required for basic operation Housed in a compact reflow compatible SMD package the transceiver requires no external RF components...

Page 4: ...ransceivers are supplied in tubes of 18 pcs Figure 2 Ordering Information TT Series Transceiver Specifications Parameter Symbol Min Typ Max Units Notes Receiver Section Spurious Emissions Per FCC 15 1...

Page 5: ...TX MODE_IND RX Sx A B C D E F G H RX MODE_IND AB TX Power up Response 80ms BC RX Initial Response 8 to 50ms with no interference CD Data Settle 4 to 8us EF Data Update Delay During Active Session 5 to...

Page 6: ...m 85 C 25 C 40 C Figure 7 TT Series Transceiver Peak Current Consumption vs Transmitter Output Power at 3 3V Figure 9 TT Series Transceiver Average Current Consumption vs Transmitter Output Power at 3...

Page 7: ...A Supply Voltage V 85 C 25 C 40 C Figure 11 TT Series Transceiver TX Current Consumption vs Supply Voltage at Max Power Figure 13 TT Series Transceiver Transmitter Output Power vs Supply Voltage 11 11...

Page 8: ...Voltage Figure 17 TT Series Transceiver RSSI Voltage vs Input Power 0 1 1 10 0 15 30 45 60 75 90 105 120 135 150 165 180 195 210 225 240 255 Average Current mA Duty Cycle s 2 5VDC 3 0VDC 3 3VDC 5 0VD...

Page 9: ...be left unconnected 21 RSSI O Received Signal Strength Indicator This line outputs an analog voltage that increases with the strength of the received signal It is updated once a second 24 POWER_DOWN...

Page 10: ...DIVIDER MODULATOR GAUSSIAN FILTER fDEV DIVIDER LNA ANTENNA GPIO INTERFACE LDO VCC PDN INTERFACE VOLTAGE TRANSLATION Figure 20 TT Series Transceiver RF Section Block Diagram Module Description The TT S...

Page 11: ...more advanced features that are available with the serial interface 1 TRM XXX TT NC 2 GND 3 NC 4 NC 5 GND 6 NC 7 S0 9 S1 10 GND 11 S7 18 S6 19 RSSI 21 GND 22 GND 23 POWER_DOWN 24 VCC 25 S5 26 CMD_DATA...

Page 12: ...custom data is programmed into the module using a serial command Transmit Operation Transmit Operation is entered when any of the status line inputs go high During Transmit Operation the MODE_IND lin...

Page 13: ...the MODE_IND line for 10 seconds and neither of the Pairing units will store an address In this case the module should either be reset to clear the address table or the serial interface can be used to...

Page 14: ...n the reset sequence is recognized Extended Pair Completed Solid ON when the pairing operation is completed and waiting for the PAIR line to go low Figure 22 MODE_IND Timing Using the RSSI Line The mo...

Page 15: ...t to part Warning The LVL_ADJ line uses a resistor divider to create a voltage that determines the output power Any additional current sourcing or sinking can change this voltage and result in a diffe...

Page 16: ...eceiver on after it has completed some activity This activity includes completing a transmission and receiving a valid packet After KeepOn seconds have elapsed with no transmit or valid receive activi...

Page 17: ...operate as momentary or latched Add or remove specific paired devices Individually set Permission Masks that prevent certain paired devices from activating certain status line outputs Change the modul...

Page 18: ...ast received packet Read only Interrupt Mask Sets the mask for events to generate a break on CMD_DATA_ OUT Event Flags Event flags that are used with the Interrupt Mask Figure 28 TT Series Transceiver...

Page 19: ...rator is required to perform unintentional radiator testing on the final product per FCC sections 15 107 and 15 109 and IC RSS GEN Information to the user The following information must be included in...

Page 20: ...cally radiated power e i r p is not more than that necessary for successful communication The TRM 900 TT radio transmitter has been approved by the FCC and Industry Canada to operate with the antenna...

Page 21: ...GND GND GND GND GND GND GND GND GND GND GND VCC VCC GND 91k 1 GND S0 S1 S2 S3 VCC GND GND 100k GND VCC 100k 100k 100k GND GND GND GND VCC VCC VCC VCC VCC 100k VCC RX TX GPIO 100k Figure 31 TT Series T...

Page 22: ...election and location within the end product Linx offers cable assemblies with a U FL connector on one end and several types of standard and FCC compliant reverse polarity connectors on the other end...

Page 23: ...Multipath is a term used to refer to the signal cancellation effects that occur when RF waves arrive at the receiver in different phase relationships This effect is a particularly significant factor i...

Page 24: ...tric properties Since such compounds can considerably impact RF performance and the ability to rework or service the product it is the responsibility of the designer to evaluate and qualify the impact...

Page 25: ...aximum Solder Times Absolute Maximum Solder Times Hand Solder Temperature 427 C for 10 seconds for lead free alloys Reflow Oven 255 C max see Figure 40 Reflow Temperature Profile The single most criti...

Page 26: ...d configuration constraints In these instances a designer must make the best use of the area available to create as much ground OPTIMUM USABLE NOT RECOMMENDED NUT GROUND PLANE MAY BE NEEDED CASE Figur...

Page 27: ...les Linx offers a wide variety of specialized antenna styles Figure 46 Many of these styles utilize helical elements to reduce the overall antenna size while maintaining reasonable performance A helic...

Page 28: ...testing laboratories across the country Many labs can also provide other certifications that the product may require at the same time such as UL CLASS A B etc Once the completed product has passed an...

Page 29: ...stomer including without limitation breach of contract breach of warranty strict liability or negligence Customer assumes all liability including without limitation liability for injury to person or p...

Reviews: