Drain Blockage and Leak Detection Alarms
When treating hard water, scale may accumulate in the drain valves or drain line causing leaks to the drain or a plugged drain
line. The LCM-140 detects drain line plugging and leaks to the drain. If a drain plug is detected, the LCM system will
shut-down and all four indicator lights (blue and red) will blink in unison. For the LCM-140 model, if a drain leak is detected,
indicator lights C and D will blink. If either alarm is observed, reset the system by repowering it. This is done by detaching
and reattaching the power cord at the rear of the LCM. If the alarm occurs again, contact your Authorized Dealer for
maintenance.
Section 6:
Troubleshooting
Observation
Causes/Remedies
No Water Flow
No Green Power Light
No power; unit not plugged into required 100-120V outlet.
Fuse blown (6 A slow blow fuse).
Remedy – Replace fuse
Electronics failure.
Remedy – Call your Authorized Dealer
Four blue and red Indicator Lights
Flash up and down
The system is conditioning the LINX 100 TDS cartridges; this process takes
90 minutes.
No or Low Product Water Flow
(Green light on; no indicator lights are
flashing when tank drawing water)
Tubing connections are incorrect
Insufficient feed water pressure (<20 psi).
Remedy –Call your Authorized Dealer to install a booster pump
No Product Water Flow
Indicator lights C and D flashing
Leak detected (LCM-140 models only)
Remedy – If occurs again after re- powering, call Authorized Dealer
No Product Water Flow
Indicator lights A, B, C and D flash
Clogged drain line (drain valve(s) or tubing)
Remedy – If occurs again after re-powering, call Authorized Dealer
Light other than power light
continuously on
LINX 100 Sediment filter, LINX 100 or 110 Carbon filter, or LINX 100 TDS
cartridges have surpassed their usage volume limits
Remedy – Call your Authorized Dealer to replace cartridges and/or filters
Objectionable Taste or Odor
LINX 100 or 110 Carbon filter is missing or exhausted.
Remedy – Call your Authorized Dealer to replace the carbon filter
Poor TDS reduction
Dial-a-Taste knob set to high mineral level (rotated clockwise).
Missing or damaged bottom LINX 100 TDS cartridge o-ring
Excessive flow rate for feed TDS (wrong flow restrictor used)
LINX 100 TDS cartridges need replacement.
Leak Out Top of Cell Lid
LINX 100 TDS cartridge not completely inserted.
Remedy – Twist lids clockwise until they stop (main rib points front-back)
Top cap o-rings not sufficiently seated in grooves
Remedy – Replace top cap o-rings
Rapid Clicking Noise (Indicator lights
moving back and forth)
The system is cleaning its valves by rapidly opening and closing them. The
process takes one minute to complete and occurs every 130 gallons of water
production.