20
21
There are several settings that must match in order for the modules to be
able to communicate. This example uses the following settings.
•
The Encryption Key must match on both modules. This can only be
read out of an AP.
•
Network ID must match on both devices.
•
The UART Baud Rate is 9600.
Other settings can be used as long as they match on both modules. Once
the settings are changed and submitted to both modules, the Network tab
can be used to graphically view the network topology and the Wireless
Chat tab can be used to transfer data.
Figure 25: The Master Development System Software Dragging to Change the Active Module
Clicking on the Network tab shows the current state of all modules
connected to the PC.
Both modules are set as End Devices. There must be at least one
Access Point in every network, so one module must be changed. This is
accomplished by clicking the drop-down menu on one of the modules and
selecting AP.
Both modules must have the same Network ID, so change the ID number
in one or both of the boxes to match.
Figure 26: The Master Development System Software Network Tab
Figure 27: The Master Development System Software Network Tab