Liquid Mass Flow Controller   

Instruction Manual 

 

LC-3000L Series 

  

   

 

Safety precautions 

 
Incorrect handling may cause death or injury.

 

 

(1)   Before connecting the fittings, check that no damage or defects are found on 

the fittings. Make connect properly and make sure that leak test is conducted 
before actual operation to prevent fluid from leaking into the atmosphere 
(Hereafter, the measured fluid is called “liquid” or “fluid”). 

(2)   

DO NOT

 apply any fluids corrosive to the wetted materials. Corrosion may cause 

fluid to leak into the atmosphere. Check the liquid type to be used in advance. 

(3)   The device is not designed as an explosion-proof structure. 

DO NOT

 use device in a 

where explosion-proof structures are required. Doing so may cause fire or explosion. 

Incorrect handling may lead to medium or slight injury or may 
cause damage to, or loss of, facilities or equipment.

   

 

(1)   Observe the precautions listed in the WARNING (above) 
(2)   Strictly observe the electrical specifications. Not doing so cause fire, damage to 

sensors or malfunction. 

(3)   This device is not designed to be waterproof. 

DO NOT

 locate this device outdoors or 

in a place where it may be splashed with water. Doing so may cause fire, trouble or 
malfunction of this device. 

(4)

   DO NOT 

modify this device. It may cause fire or other problems. 

(5)  While a power supply is applied to the device, +15VDC and -15VDC must be 

applied simultaneously. If only +15VDC or -15VDC is applied, electronic 
circuits will become unstable and it may cause a malfunction.   

(6)  This device is not designed to handle hot swap. Please avoid attaching and 

removing the power supply connector and interface connector with the power 
switched on. Attachment and/or removal with the power on may result in 
failure of the device. 

(7)   This device is a precious device, please handle it carefully. Dropping down or 

handling it carelessly will cause damage. Please use assist instrument while moving 
or setting the device.

 

(8)   Regular maintenance is recommended for continuous use of this device 

(Recommended frequency is once a year).

 

 

1. Introduction 

This manual explains basic operation of the Liquid Mass Flow Controller LC-3000L 
Series (Hereafter, it is called "LC").   
Please read through this manual and the separate volume “The Digital Interface Manual” 
carefully to become familiar with the features of this device. 

 

2. Summary 

The LC

 

is high performance mass flow controller for gas using thermal 

flow sensor and high response piezoelectric valve. 

 

3. Features 

The LM has the following features. 

 

(1)   LINTEC’s original ambient temperature compensation mass flow sensor is 

incorporated for measuring flow rates. 

·

 

Low sensor temperature, long-time steady monitor, and few problems such as 

    degradation of gas to be monitored.   
·

 

The effect of ambient temperature is less because the sensor temperature is kept at   

    the ambient temperature. 
·

 

Steady temperature distribution of sensor and high-speed response.   

(2)   Digital control by microprocessor and high-resolution A/D, D/A converter;   

  

·

 

High functionality 

  

·

 

By setting of device number (address), multiple devices can be controlled through   

 

      

a single interface 

  

·

 

Many added functions such as flow totalizer, auto-zero , and ramping function etc.   

(3)   Universal digital interface 
(4)   Superior corrosion resistant sealing materials make maintenance easy. 

        Metal seals (Stainless Steel 316L) are used 

(5)   Particle free structure 
(6)   By using a metal case and various types of filters, steady operation can be achieved 

even in an environment of high-frequency noise and stationary magnetic field 

(7)   RoHS compliant 
(8)   Bypass-less construction (Easy liquid feed and internal purging. mounting   

direction: free) 

 

 

 
 
 
 
 
 
 
 

4. Specification/ Dimensions 

             

(1) Specification 

Product name 

Liquid Mass Flow Controller 

Model 

LC-3102L 

LC-3202L 

Precursor type and Fluid & flow 
rate  (except  HCl,  HF  and  other 
liquids which corrode stainless steel) 

C2H5OH

 

0.1 to 1.0g/min F.S. 

H2O 0.1 to 0.2

 

g/min F.S.

 

C2H5OH

 

1.0 to 2.0g/min F.S. 

H2O 0.2 to 0.4

 

g/min F.S.

 

Operation of external valve 

Piezo actuator / Normally Open 

Surface treatment   

NO: No treatment (no surface treatment) 
MO: Precision polishing 

Minimum control flow rate 

5% F.S. 

Analog flow rate setting signal 

0 to 5VDC (Proportional to flow rate) 

Analog flow rate output signal 

0 to 5VDC (Proportional to flow rate) 

Accuracy (Note1) 

±1.0 %F.S. 

Repeatability (Note1) 

±0.5 %F.S. 

Operating  differential  pressure 
(Note1) 

50 to 300 kPa(D) 

Maximum  operating  pressure 
(Note1) 

300 kPa(G) 

Pressure Limit 

1MPa(G) 

Operating temperature & Humidity 
(Note2) 

15 to 35°C· 0 to 80%RH 

(Dewing should be avoided) 

20 to 30°C· 0 to 80%RH 

(Dewing should be avoided) 

Temp.    coefficient 
(Note2) 
(Reference Temp.25) 

Zero 

±

0.1 %F.S./

 

Span 

Leak integrity 

Less than 1×10

-11 

Pa

· 

m

3

/sec (He) 

Recommended gas for pushing 
the liquid (Note3) 

He 

Storage temperature& Humidity 

0 to 60 °C 

· 

0 to 80 %RH (Condensation should be avoided) 

Mounting direction 

Free 

Wetted materials 

Stainless Steel 316L, 

PCTFE 

Stainless Steel 316L, 

PFA, Ni-Co 

Seal materials 

Au 

Fittings 

3.2mmVCR(male), 6.35mmVCR(male), 3.2mmSWL 

Digital interface connector 

RS-485 (RJ45 modular jack)

 

 2-wire system 

Power supply 

+15VDC±3% 100mA, -15VDC±3% 50mA 

Inrush current 
(Actual measurement value) 

+15V: 11A 130 µs      -15V: 9A 110 µs 

Analog interface connector 

D-sub connector (Fixed size of screw M3) 

Weights 

Approx.1kg 

             

Note

 

     

1) When using as a liquid controller for vaporization system, please refer to the specification   

       

              

sheet of vaporization system. 

         

Note

 

     

2) The flow rate will be not accurate if the liquid temperature is different from surrounding   

         

      

temperature when measuring or controlling, please set the same temperature for liquid and the 

         

       

device. 

  Note

 

  

3) There is the possibility of failure about measuring and controlling. To reduce the gas solubility of 

           

 

the liquid, Helium

 

(He) is recommended to be the pressurized gas.   

           

· 

Connect the LC to the frame ground. 

           

· 

Flow rate calibration is done by C2H5OH or H2O. 

           

· 

Liquid with solid materials can’t be controlled.   

           

· 

If the mixture ratio of mixture liquid is changed, please consult us in advance. 

           

· 

If there are particles in the target liquid, install a filter to remove particles more than 0.2μm on the 

                  

primary side (the inlet side). 

           

· 

The viscosity of liquid controlled by the LC should be less than 0.1Pa·s (100cp). Please consult us if 

 

         

the viscosity of liquid is high. 

           

· 

Please feed in the liquid after completely purging (Recommended). 

 

           

(2) Dimensions

 

 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

                   

3.2mm VCR (male) 112mm specification 