Step 5: Whilst supporting the top of the heatsink place a 

hand at the bottom and pull the whole module 
outwards, maintaining the angle shown in the 
photo. Note: the weight of the module is taken by 
resting the two pins on the cabinet (see below). 

 
 
 
 
 
 
 
 
 

 

 
 
Step 6: Lay the module flat on a soft surface, taking great 

care not to damage the veneer on the rear of the 
cabinet.  Note how it has been laid on a piece of 
foam to protect the paint on the heatsink. 

 
Step 7: To change the remaining two fuses, it is necessary 

to partially remove the top screening can. Remove 
all 4 screws (1 at each corner) and the lift the end 
of the screening can upwards in the direction 
shown. Note: the cables at the end that are cable-
tied may restrict the movement of the screening-
can.  

 

 

 
 
 
 
Step 8: There are two power-supply boards, each with a 

fuse behind the inlet socket (see picture), change 
both fuses, as earlier, if there are 6.3amp fuses 
fitted these should be changed for 10amp MISS 
397’s. 

 
 
 
 
 
 
 
 
Step 9: Replace the screening-can and re-fit the four 

screws 

 
Step 10: The amplifier module is now ready to be 

assembled back into the cabinet. Before picking up 
the module, note how the cables should lie relative 
to the support pin. 

Fuse 
locations 

Lift this screening 
can 

Lift screening 
can at this 
end as 
indicated 

 
 
 
 
 
 
 
 
 
 
 
 