background image

 

 

 

Instruction manual 

 

User information 

 

Aqua Wheel 0,55 kW – 1,1 kW

 

 

Wasser – und Abwasserbelüfter 

Water and Wastewater Aerator 

 

 

 
 
If the type of aerator you have purchased requires installation or assembly prior 
to commissioning, please observe the enclosed installation instructions. These 
instructions must be read and followed first. 
 
The  aerator  was  manufactured  to  circulate  and  aerate  water  or  waste  water. 
Any other use is fundamentally excluded and prohibited. 
 
A professional inspection before commissioning must ensure that the required 
electrical  protective  measures  are  in  place.  A  residual  current  circuit  breaker 
(FI)  with  a  tripping  rated  current  of  up  to  30  mA  is  mandatory.  The  voltage 
specified  on  the  unit  type  plate  must  match  the  existing  mains  voltage.  In 
standard  design,  all  units  are  delivered  completely  connected  and  ready  for 
operation.  All  units  are  equipped  with  motor  protection  (thermal  overload 
protection)  (either  as  a  motor  protection  plug  at  the  end  of  the  cable  or  as  a 
thermal sensor in the motor winding). If you have purchased units without motor 
protection  or  with  a  free  cable  end  at  your  own  request,  the  motor  protection 
and/or plug must be fitted by a specialist before commissioning. 
 
Attention! Rotating impellers! 
Always disconnect the mains plug before carrying out any work on the aerator! 
Otherwise there is a risk of injury! 
 

 
Electrical Connection 

The connection of the “

Aqua-Whee”l

 to an electrical supply should be made as with 

any  other  water-circulating  pump.    It  is  essential  to  use  an  ELCB.    Repair  of  the 
electrical  connection  or  motor  (after  the  expiry  of  the  manufacturer’s  warranty) 
should only be carried out by the manufacturer or a qualified electrician. 

 

Assembly 
 

Do not connect the unit to the electrical connection on site before assembly! 
 
For transport and packaging reasons, we deliver the aerator in two parts: 
 
Float and motor assembly complete with cover. 
 

 
 
 
The  assembly  is  done  in  a  few  simple  steps.  All  you  need  is  a  13  mm  open-
ended spanner and the enclosed 30 mm open-ended spanner. 
 
a)  The  front  of  the  "Aqua-Wheel"  aerator  is  where  the  single,  large  carrying 
handle of the float is located. Please turn the complete frame (motor part with 
cover) so that the highest point of the cover is at the front. The shaft ends then 
protrude to the left and right over the float. 
The frame can be moved on the float in the guide. The holes in the frame must 
match the holes in the guide on the float. 
If you fix the frame in the front setting, the unit runs with the smaller circulation 
capacity - the rear setting is the normal capacity of the unit. 
To fix the motor part on the float, you must first remove the cover. To do this, 
loosen the wing screws at the front and back of the cover. The cover can then 
be  removed.  Now  insert  the  four  long  screws  (90mm,  two  on  each  side)  and 
tighten the nuts with a spanner (do not forget the washers and spring washers). 
 
b)  The  impellers  are  supplied  loose.  They  only  have  to  be  put  on  the  shaft 
ends. The 0.55 kW unit has one wheel on each side, the 1.1 kW unit requires 
two wheels on each side. 
Please note that the open sides of the blades must always face forwards! The 
impellers must be mounted in the same way! 
With the aid of the 30 mm open-ended spanner, you must tighten the nuts on 
the impellers and thus secure the wheels on the shaft. 
The unit is now fully assembled and can be put into operation. 
 
c) The 1.1 kW unit also contains a spacer at the back of the U-float. This part 
must not be removed. 

 

First use 
a

) Ropes are needed to secure the Aqua-Wheel in its position. To fix the device, 

attach the ropes to the designated attachment points on the corners of the float or 
on the grab handles. Make absolutely sure that the ropes or cable do not come into 
contact  with  the  paddle  wheels.  The  anchorage  points  of  the  ropes  should  be 
approximately level with the water surface. Lay the power cable in such a way that 
damage is avoided. 
 
b) Check the direction of rotation. The mounted motor protection plug is equipped 
with a phase inverter. If the paddle wheels turn the wrong way round, please pull 
the plug out of the socket. At the front of the plug you can then simply swap two 
current-carrying poles with a screwdriver. This corrects the direction of rotation 

 

Power rating 

kW 

0,55 (0,40) 

1,10 

Power take-up 

840 (600) 

1400 

Voltage 

230/400 

230/400 

Motor 

rpm 

920 

920 

Minimum water depth 

0,30 

0,50 

Suction depth 

1,5 (1,0) 

1,8 

Active zone 

70 (50) 

100 

 

 