Linn Aqua-Hobby Operating Instructions Download Page 4

 

Water Aera tor 

Operating Ins truc tions  

(Tra nslation of the opera ting ins tructions) 

 
           

“ Aqua-Hobb y”/ “ Aqua-P ilz” 

 

         

                                                                     

 

 
 

This user information should be read and observed before installation and use of the 
apparatus supplied.

 

 
Should your chosen aerator require assembly before operation, please read carefully the 
separate assembly information enclosed.  These guidelines should be read and followed first. 
The aeration apparatus has been manufactured to circulate and ventilate water. Any other 
use is absolutely prohibited. 
Before operation, examination by a qualified technician should take place to ensure that 
necessary electrical precautions are available.  An electrical fault switch (FI) with a nominal 
current of up to 30mA is stipulated.  The voltage displayed on the label of the apparatus must 
agree with that of the mains voltage.  Standard models are delivered completely sealed and 
ready for use.  All apparatus are equipped with a motor (overheating) protector (either by a 
motor protection device attached to the cable end or by a heat sensor inside the motor itself).  
If you have received apparatus without motor protection or with a free cable end, then a 
qualified technician should install the motor protector and/or attachment before operation. 
 

Installation on water 

For installation purposes, you will require two tension proof ropes.  These ropes must be 
secured to the apparatus.  Some apparatus have loops fitted for this purpose.  Otherwise, 
they can be attached to carrying handles on the floats or to the screen basket.  The ropes 
should be secured so that they cannot under any circumstances come into contact with the 
propeller. 
After ropes have been fitted to both sides of the apparatus, it can be positioned in the water.  
The connection cable should be positioned in such a way on the sides of the apparatus that it 
will not be pulled into the water.  Under no circumstances must the apparatus be connected 
to the mains at this point! 
With the help of the two ropes, the apparatus can be fixed into the desired position and the 
ropes secured on the sides of the pond.  Warning –  Be sure to attach securely so that the 
apparatus cannot swivel round and damage the connection cable.  Under no circumstances 
should the connection cable be used to anchor the apparatus! 
 
Before connecting the aerator to the mains, please ensure that no one remains in the water.  
Working on the aerator while in the water (in particular, swimming to the apparatus or 
clambering onto the aerator) is strictly prohibited on the grounds of safety.  Warning!

 

 

Injury risk.  For small pools/ponds, touching of the apparatus while in operation is prohibited. 
 
The water/waste aerator can now be connected to the mains.  Warning – Please ensure that 
the plug connection is dry. 

 
It may happen that in the case of 400V models, the direction of rotation of the motor is 
incorrect.  This is immediately recognisable (no water is thrown out from the upper surface of 
the aerator).  The mounted motor protection plug is appointed with a phase reverse. 
Please pull the plug out. In front of the plug you can exchange the two live poles with a 
screwdriver. The rotational direction will be corrected. 

 
Maintenance

 

All water aerators supplied require little or no maintenance.  From time to time simply clean 
all parts of the apparatus.  To do this you must remove the apparatus from the water.  
Warning – first disconnect from the mains! 
 
If the apparatus is supplied with a screen, this, in particular, should be kept clean, for perfect 
functioning of the apparatus can only be assured if the surface of the screen is clean. 
At least once a year, the apparatus should be examined for perfect running of the propeller 
and, in the case of submersible motors, for the condition of the motor’s watertight flanges.  If 
you experience any problems, please contact us. 
 

Guarantee 

This apparatus carries a 12-month guarantee  of proper use.  A change to the apparatus or 
opening of the motor parts is prohibited and renders the guarantee invalid.  We can accept 
no liability for damage and losses incurred as a result of breakdown of the aerator.  The 
operator is advised to obtain protection (an alarm system), which would alert them to any 
eventual breakdown of the apparatus. 
 

Further Information

 

We would advise you that, in accordance with product liability law, we do not accept liability 
for damage caused by our apparatus, if the information and advice given within these 
operating instructions has not been followed. 
 
The aerator should never be pulled, carried or fixed into place, by the connection cable.  Only 
suitably qualified persons should  carry out replacement of the connection cable.   The 
connection lead should be no lighter than a rubber hose HO7 RN-F (EN 60335-2-41).  Avoid 
wear and tear on the connection cable! 
 
The electric lead should be kept in an area where there is no risk of flooding and should be 
protected from damp.  Connection cable and plug should be examined for damage before 
use. 
 
The aerator should not be operated out of water! In the event of aerator defects, repairs 
should be carried out only by the manufacturer or by an authorised dealer.  In addition, only 
original spare parts should be used. 
 
The aerator is fitted with a rubber over-current device, designed to protect the motor from 
overload. It is fitted next to the round site plug, and has a reset button. It is not weatherproof, 
and should be protected from rain and direct sunlight. If the overcurrent device trips out the 
power to the aerator, investigate the cause promptly. Repeated pushing of the reset button, 
may damage the motor. Consult your supplier about servicing the motor. Removal of the 
overcurrent device will invalidate the warranty.  

 
 
 
 

 

Reviews: