![LinMot EM01-48 Installation Manual Download Page 26](http://html.mh-extra.com/html/linmot/em01-48/em01-48_installation-manual_1925369026.webp)
Installation Guide Linear Modules
ENG
Page 26 / 36
EM01-48
NTI AG / LinMot
8.3.2 Linear Motor (Stator and Slider) Cleaning and Lubrication
1. Clean slider with disposable paper and LU06 cleaning spray. Move the stator to side to access all soiled
parts.
2. By moving the stator over cleaned parts of the slider, a residual soil from the stator bore will be smeared
out soiling the slider again. Repeat step 1 and 2 until entire remaining residual soil from stator and slider
is removed.
3. Grease the slider with grease LU02 so, that the lubricating film of grease is visible. Move the stator through
entire stroke on the slider. If no lubricating film is visible on the slider, repeat.
Do not overlubricate!
Remove any excessive grease while moving the stator.
The EM-Modules can normally be cleaned and lubricated without disassembling. If the parts are heavy soiled
and cannot be cleaned without disassembling, do the following:
1. Remove the right side panel and slide off the carriage kit with stator.
2. Clean slider and the stator bore with disposable paper and LU06 cleaning spray. It is important that no
paper residue is left anywhere on the guide.
3. Grease the slider with grease LU02 so that the lubricating film of grease is visible.
4. Slide the carriage kit with stator cautiously back onto the guide.
5. Screw back removed side panel, use thread locking compound.
6. Move the stator through entire stroke on the slider. If no lubricating film is visible on the slider, lubricate
the slider. Repeat until small film of grease is visible.
Do not overlubricate!
Remove any excessive grease
while moving the stator.
Ordering Information
Item
Description
Item-No.
LU06-250
Maintenance spray for linear motors (250ml)
LU02-50
Lubricant for linear motors (50ml)
LU02-1000
Lubricant for linear motors (1000ml)
9 Storage, Transport, Installation Altitude
•
The storage area must be dry, dust-free, frost-free and vibration-free.
•
The relative air humidity should be less than 60 %.
•
Prescribed storage temperature: -
15 °C…70 °C
•
The motor must be protected against extreme weather conditions.
•
The air in the storage area must not contain any harmful gases.
•
The max. installation altitude is 4'000 m above sea level.