12 / 60
NTI AG / LinMot
3.1.1
Cyclic Mode Inputs 0x1A02
Index
Size
[Byte
]
Byte
Offset
Name
Data
Type
0x1A02
16
-
Variables
RECORD
0x6041
2
0
Statusword
Uint16
0x6064
4
2
Position actual value
Int32
0x1B8A
4
6
DemandPosition
Int32
0x1B93
4
10
DemandCurrent
Int32
0x6061
1
14
Mode of Operation display
Byte
0x000
1
15
Byte Padding
Byte
This module could be used to map the inputs of an CiA402 NC axis.
3.1.2
User Defined Inputs 0x1A20
Index Size
[Byte]
Byte
Offset
Name
Data
Type
0x1A20 2..32
-
Variables
RECORD
1..8
User defined Parameter/Variables accessed by
UPID
The PDO 0x1620 could be used, to read Variables/Parameters for which no predefined
PDO exists. It is possible to map 1 to 8 entries defined by its UPID in this PDO. Allowed
are only 16 or 32 bit entries. The defined Size of the data has to match with the size,
defined by the UPID.
3.1.3
Default Inputs 0x1B00
Index
Size
[Byte]
Byte
Offset
Name
Data Type
0x1B00
18
-
Variables
RECORD
0x1B62:00
2
0
StateVar
Uint16
0x1D51:00
2
2
StatusWord
Uint16
0x1D8E:00
2
4
WarnWord
Uint16
0x1B8A:00
4
6
DemandPosition
Int32
0x1B8D:00
4
10
ActualPosition
Int32
0x1B93:00
4
14
DemandCurrent
Int32
The Default input PDO mapping of 18 Bytes the index is the UPID value of the variable.
3.1.4
NC Inputs 0x1B01
Index
Size
[Byte]
Byte
Offset
Name
Data Type
0x1B01
18
-
Variables
RECORD
0x1B62:00
2
0
StateVar
Uint16
0x1D51:00
2
2
StatusWord
Uint16
0x1D8E:00
2
4
WarnWord
Uint16
0x1B8A:00
4
6
DemandPosition
Int32
0x1B8D:00
4
10
ActualPosition
Int32
0x1B93:00
4
14
DemandCurrent
Int32