Installation Guide C1200
NTI AG / LinMot
Page 13 of 31
7.4 X3
X3
Motor Sensor / Brake
1
6
2
7
3
8
4
9
5
case
LinMot Motor:
Do not connect
Brake+
Do not connect
Do not connect
+5VDC
AGND
Sensor Sine
Sensor Cosine
Temp In
Shield
EC Motor:
Do not connect
Brake+
Do not connect
KTY
+5VDC
AGND
Sensor Sine / Hall Switch U
Sensor Cosine / Hall Switch V
Hall Switch W
Shield
DSUB-9 (f)
Note:
Use +5V (X3.3) and AGND (X3.8) only for motor internal hall sensor supply (max. 100mA).
Cable length < 30m.
Brake+ (X3.6): 24V / max.500mA, Peak 1.4A (will shut down if exceeded)
Caution:
Do NOT connect AGND (X3.8) to ground or earth!
Use Y-style motor cables only (for example K15-Y/C)!
A W-style cable has a different shielding, so it cannot be modified to a Y-style cable!