5.1.3 Overview of the Connectors
Pos. 1: E-Pusher
Pos. 2: Linear motor
Pos. 3: Rotary motor
Pos. 4: Torque sensor
Pos. 5: Force sensor
5.1.4 Connector Wiring Linear Rotary Motor
View: Motor connector, plug side
Connector wiring
Linear Motor:
C-Connector
Rotary Motor:
C-Connector
Wire color
Motor cable
Ph 1+ / Ph A
A
A
red
Ph 1- / Ph B
B
B
pink
Ph 2+ / Ph C
C
C
blue
Ph 2- / (-)
D
D (not connected)
grey
+5VDC
E
E
white
GND
F
F
Inner shield
Sin
G
G
yellow
Cos
H
H
green
Temp.
L
L
black
Shield
Housing
Housing
Outer shield
Extension cables are double shielded. The two shields of the extension cables must not be
connected together: the inner shield of the extension cables is used as GROUND and must
be connected to GROUND*; only the outer shield must be connected to SHIELD* of the
connector.