Installation Guide Linear Motors
ENG
Page 26 / 47
P01-48-HP EX protected
NTI AG / LinMot
For the purpose of complete encapsulation, the plug is welded to the motor housing. The connector on the
motor is made of stainless steel and has a thread for tightening. When plugged in, the protection class IP67
is fulfilled. The motor and cable connectors are screwed tightly together (tightening torque 5 Nm, WAF 27).
3.10 Motor cable
KS10-05/05/04-EX
Cable type
High-Flex Cable
Minimum bending radius for fixed installation
60 mm (2.36 in)
Minimum bending radius when moving
120 mm (4.72 in)
Approval
UL / CSA 300V
Material wire isolation
TPE
Material cable sheath
PUR
Oil resistance
very good
Chemical resistance (to acids, alkalis, solvents,
hydraulic fluid)
good
Outdoor durability
very good
Flammability
flame-retardant
Ordering information
Item
Description
Item-No.
KS10-EX-Y-Fe/E6k-
Trailing Chain Cable KS10-EX-Y-Fe/E6k-, Custom length
0150-3642
Item
Description
Item-No.
MC01-Y-Fe/m
Motor Connector Y-Fe/m
0150-3289
MC01-E6k/f-EX
Connerctor with hexagonal union nut
0150-3538
KS10-05/05/04-EX
Motor cable for EX applications per m
0150-9010
Summary of Contents for 0150-4370
Page 42: ...Installation Guide Linear Motors ENG Page 42 47 P01 48 HP EX protected NTI AG LinMot ...
Page 43: ...Installation Guide Linear Motors ENG NTI AG LinMot P01 48 HP EX protected Page 43 47 ...
Page 44: ...Installation Guide Linear Motors ENG Page 44 47 P01 48 HP EX protected NTI AG LinMot ...
Page 46: ...Installation Guide Linear Motors ENG Page 46 47 P01 48 HP EX protected NTI AG LinMot ...