39
Chapter 4: Storage
Network Storage System (NSS) Administrator Guide
Chapter
4
•
Health:
The system monitors each disk drive and reports the condition of the disk drive.
Options include:
-
Passed:
The disk drive has passed the S.M.A.R.T. test and is considered fully operational.
The Error LED on the disk drive is off.
-
Failing:
The disk drive has failed the S.M.A.R.T. test and is predicated to fail. The red Error
LED on the disk drive is blinking.
-
Failed:
The disk drive is not operational (has failed). The red Error LED on the disk drive is
on solid.
•
Status:
The state of use for the disk drive. Options include:
-
Online:
The disk drive is spun up.
-
Standby:
The disk drive is idle and is spun down.
-
Offline:
The disk drive is failed.
•
Action:
There are available action buttons associated with each installed disk drive:
-
Get Details:
View the current, detailed S.M.A.R.T. report for the disk drive.
-
Locate:
Send a locate request to the applicable disk drive. The white disk drive LED on the
front of the NSS chassis blinks for the targeted disk drive. (Note that only one locate request
can be sent at a time to ensure that you can easily spot the desired disk drive. Disk drives