960-3100-00
iPonic 614 Installation Manual
28
CO
2
Night Setpoint
To prevent a large deficit of CO
2
when your day setpoint begins you may want to enable a night CO
2
target that will be higher than the default of zero parts per million but lower than your day CO
2
target.
Photosynthesis does not occur in the dark, but a night CO
2
setpoint can give your environment a “head
start” by not allowing CO
2
levels to fall too low. An alternative way to achieve this could be by settings a
third differential (DIF) setpoint. See Advanced Timing Control in this Advanced section of the manual
Enabling CO
2
Night Setpoint
Menu->SystemSetup->6. Advanced->button 7 for Adv. Setpoint Settings->button 1 to Enable/Disable
Changing CO
2
Night Target Once Enabled
Menu->1. Current Setpoints->3. CO2 Setpoint->button 4 for Switch Period->Select “Night” with wheel
Press OK->button 5 for Set CO2 Setpoint->wheel to change (press one to change increment)->OK->OK
again will prompt to save-> OK to save settings
Advanced Humidity Control
Override Settings
Menu->SystemSetup->6. Advanced->GlobalHumiditySettings->Set On Duration and Off Duration
Deadband
Menu->SystemSetup->6. Advanced->GlobalHumiditySettings->SetDeadband as %RH (Press 1 to
change increment)
Additional Programming for Humidity Settings
You have the option of choosing which temperature and humidity regulating equipment is on during each
possible humidity stage, just as you can choose which temperature and humidity regulating equipment is on
during each cooling or heating stage. (Refer to
Advanced Temperature Control
section) The three humidity
stages are humidify, dehumidify and cold dehumidify. For each humidity stage, you will need to choose whether
to override your temperature stage settings and force the chosen equipment type
on
, override your temperature
stage settings and force the chosen equipment type
off
or not force a change to that piece of equipment during
that stage and allow the temperature stage settings to make that determination. If “Stages” is not a main menu
option and you would like to tell your controller which equipment to run in each of these humidity stages, please
see the section titled
Programming Additional Temperature Stages
for instructions on enabling this menu
option.
Menu->Stages->2. Humidity Stages->use buttons 5, 6, 7 & 8 to select stage and equipment type, press
button 3 “Setup” and choose Override Off, Override On or No Change. Press OK. When you are done
making changes press OK. Press OK again to save your changes.
Advanced Irrigation Control
Advanced Irrigation Settings
From the home screen of your iPonic
TM
614, press the menu button. Select option 4, “System Setup” with
the wheel and press OK. Select option 1, “Equipment Setup” by pressing OK. Select option 2, “Advanced”
with the wheel and press OK. Select option 3, “Irrig Pump” with the wheel and press OK. Press button 2
“Irrigation”. Press button 1 to enable irrigation cycling. Use buttons 5 & 6 to set your irrigation start and
end times. Press button 7 to set the duration the water should be on during each irrigation cycle. Press
button 8 to set the duration the water should be off during each irrigation cycle.
Once Daily or Single Event Irrigation
See
Once Daily or Single Event Overrides
in the
Advanced Timing Control
section of this manual.