![LINK-MI LM-HD808-4K Operating Instructions Manual Download Page 7](http://html1.mh-extra.com/html/link-mi/lm-hd808-4k/lm-hd808-4k_operating-instructions-manual_1923385007.webp)
cir_6x\r\n
s7y
Output 7 select input 1~8
“x” : indicate the input port, range from 0~7.
“y” : indicate the input port, range from 1~8.
cir_7x\r\n
s8y
Output 8 select input 1~8
“x” : indicate the input port, range from 0~7.
“y” : indicate the input port, range from 1~8.
asw_x\r\n
s1y
s2y
s3y
s4y
s5y
s6y
s7y
s8y
All output select input x;
“x” : indicate the input port, range from 0~7.
“y” : indicate the input port, range from 1~8.
bc_\r\n
s1x
s2x
s3x
s4x
s5x
s6x
s7x
s8x
Obtain the input status.
“x” : indicate the input port, range from 1~8.
sed_x_y\r\n
sed_x_y
Copy edid from “x” to “y”,
“x””y” range from 0~7
rst_\r\n
Reset factory settings.
666
) Web password reset
The command length is 4 bytes.
rpw+ ‘
↙’
“
rpw” is the key word , ‘
↙’
is carriage return.
When you send the Web password reset command to
LM-HD808-4K
, if succeed, it will feedback "rpw", and the
web password will be set as "0000000000".