background image

Antennas

Radio Antennas

Antenna arrangement is crucial to quality radio reception, and AM and FM antennas should be placed at the highest point of the roof and at least 
six feet away from any electrical or intercom wiring.  VMC1 requires two antennas, one for AM and one for FM reception. The AM antenna is 25-foot 
in wire length, and the FM antenna is a 25-foot length of coax with a “T” shaped wire dipole at one end that attaches between rafters in the attic.

IMPORTANT! Isolate the antenna leads from the intercom station cables by running them through a separate hole in the ceiling plate.  If grouped 
together, the intercom station cables can shield the antenna leads resulting in poor radio reception. Also keep the antenna leads away from metal 
duct work and aluminum backed insulation, which reduces reception.

AM ANTENNA 

1.  Unroll and examine the 25-foot AM antenna wire.
2.  Create a large loop with the antenna wire in an 

appropriate location, ideally in an attic.  Note that the 
length of the antenna wire can be extended by splicing 
any insulated wire onto the ends of the provided 
antenna wire.

3.  Route the two ends of the antenna down through the 

hole in the ceiling plate, down the stud bay to where 
the VMC1MB was installed.  Avoid running it parallel to 
the AC power lines and intercom CAT5 cables as this 
may interfere with radio reception.

NOTE: the overall length of the antenna wire may be extended 
by splicing on to the ‘open’ end of antenna with insulated wire. 
The gauge end of the wire should be strong enough to support 
it without breaking. 

NOTE: Some customers may want to use an external tuned loop 
antenna or vertical amplified broadband antenna. Refer to those 
manufacturer’s installation instructions for further information.

FM ANTENNA

1.  Unroll and examine the FM antenna. The antenna is 

formed by spreading the red and black wires at the 
end of the COAX. The terminal lug at the end of each 
wire is for screw mounting the wires outstretched.  The 
antenna is provided with an F type connector allowing 
for easy connection of additional cable.

2.  Route the connector end of the antenna COAX ( RG 

6 or RG 59 ) down through the hole in the ceiling 
plate, down the stud bay, and on the right side of 
where the VMC1 Master Unit will be installed.  

3.  Connect the included 75 Ohm to 300 Ohm adapter to the end of the cable.  

 

NOTE: Some customers may want to use an external tuned loop antenna or vertical amplified broadband antenna. Refer to those manufacturer’s installation 
instructions for further information.

CAT5 TO

STATIONS

AM ANTENNA WIRE

FM ANTENNA

DIPOLE

WALL HOUSING

(VMC1HC )

CEILING

PLATE

VMC1 Antenna 

Figure 7

 WARNING 

ALL AC ELECTRICAL CONNECTIONS TO THE POWER SOURCE TE6D POWER SUPPLY MUST BE MADE BY A LICENSED ELECTRICIAN AND 

MUST OBSERVE ALL NATIONAL AND LOCAL ELECTRICAL CODES

17

Summary of Contents for M&S VMC1

Page 1: ...5 USA Canada 800 421 1587 800 392 0123 760 438 7000 Toll Free FAX 800 468 1340 www linearcorp com VMC1 Video Security Intercom system for the home Rough In Instructions Video Security Intercom system...

Page 2: ...p static charges Section 810 of the National Electrical Code ANSI NFPA No 70 1984 provides information with respect to proper grounding of the mast and supporting structure grounding of the lead in wi...

Page 3: ...system damage DO NOT STAPLE CABLES Staples cause shorts DO NOT SPLICE CABLES Splices are unreliable and defeat the signal isolation properties of the cable DO keep cables at least 18 inches from fluor...

Page 4: ...llation 11 Wood Frame Unfinished 11 VMC1MB Station Rough In 12 VMC1MB Installation 12 TE6D Power Supply 14 Power Supply 16 Radio Antennas 17 Room Station Auxiliary Activation 18 Door Station Rough In...

Page 5: ...Diagram VMC1 Block Diagram AM ANTENNA FM ANTENNA DEDICATED POWER MASTER STATION TE6D POWER SUPPLY TERMINAL BLOCK 5 ROOM STATIONS DOOR STATION VIDEO DOOR STATION DOOR LOCK RELAY DRW VMC1 Block Diagram1...

Page 6: ...eo Intercom Package Rough In Kit 1 VMC1MB Master Station mounting bracket 1 TE6D Power supply 1 101093 FM dipole antenna 3 1 226804 300 ohm to 75 ohm F female Balum 1 250106 2 AM Antenna wire Orange 2...

Page 7: ...nded for installing room stations in new construction or installations where the drywall has not yet been installed TOOLS Most are required for purposes of this installation but may vary according to...

Page 8: ...s have integrated RF filters or special design that prevents demodulation of high frequency carriers The use of microwaves cell phones cable television bug zappers even heating pads in close proximity...

Page 9: ...AM FM ANTENNAS The antenna arrangement is critical to the installation for quality radio reception Place AM and FM antennas at the highest point of the roof and at least 6 feet away from any electrica...

Page 10: ...other system faults MAXIMUM LENGTH FOR CABLE RUNS The system can be home run wired from a central point or daisy chained from station to station However the number of stations on a daisy chain run gov...

Page 11: ...or wall tiling around the Master Station ensure the Master Station is mounted either completely within or clear of tile to avoid an uneven surface VMC1MB Wood Frame Unfinished Install the VMC1MB flush...

Page 12: ...he Master Station is mounted either completely within or clear of tile to avoid an uneven surface VMC1MB See Figure 2 Create a template by laying the VMC1MB face down on a flat surface and draw measur...

Page 13: ...consists of more than 5 room stations Linear recommends using the optional Linear H628 8 stations or DMD 16 16 stations Data Distribution module The recommended wire color convention is recommended T...

Page 14: ...ower Supply 3 Use wire nuts to connect the incoming power cable to the TE6D transformer BLACK HOT and WHITE NEUTRAL input wires 4 Connect the GREEN GROUND wire to the ground conductor 5 Secure all pow...

Page 15: ...E TE6D POWER SUPPLY MUST BE MADE BY A LICENSED ELECTRICIAN AND MUST OBSERVE ALL NATIONAL AND LOCAL ELECTRICAL CODES VMC1MB Installation TE6D Power Supply Unit up VMC1MB Mounting Bracket installpowerun...

Page 16: ...x pin connector and a two pin connector The six pin connector is the low voltage 13 8 V 3 8 amp output from the TE6D Power Supply Unit Position 4 is the Black zero volt Negative onnection to the Maste...

Page 17: ...ables as this may interfere with radio reception NOTE the overall length of the antenna wire may be extended by splicing on to the open end of antenna with insulated wire The gauge end of the wire sho...

Page 18: ...d cutoutanopeningtotheinsidedimensionsoftheVMC1HRutilizingtheinsideoftheboxasaguide approx 8 x35 8 See Figure 7 FINISHED WALL Identify the location where the room station is to be installed 1 Cut a 3...

Page 19: ...izontal viewing camera into a door chime station It is normally mounted at a height from the floor of 55 60 Installation of these units on an exterior wall requires the use of the VMC1HR rough in box...

Page 20: ...18 gauge wire to the Normally Open NO post on the mini relay 5 Connect a red 18 gauge wire to the Common C post on the mini relay 6 Install the optional DRW into the door frame following the included...

Page 21: ...le Standard weather resistance IP30 Metal Alloy VMC1VDS Plexiglas weather shield increases the weather resistance of VMC1VDS to IP31 Smoke Color VDSWS T Color video door station with 10 door chimes a...

Page 22: ...here video is not required Standard weather resistance IP30 VMC1DS BZ Bronze VMC1DS S Silver pictured Metal mounting box for room and video stations except VMC1VDS VMC1HR Steel Starter Kit for VMC1 Se...

Page 23: ...5415 Video Encoder Emails snapshot of person pressing doorbell and providing a live video feed to an IP address ENC D1POE Color video camera Durable Color outdoor camera with night vision providing 5...

Page 24: ...l Output switched 110V outlets for lights and other notification devices Remote Turn On for Lights AC1 1 outlet AC3 2 outlets MFG Xantec Niles Wire Relay The 284 Leaded Accessory Relay is a 5 amp Form...

Page 25: ...oval installation or reinstallation ANY PRODUCT RETURNED TO LINEAR LLC WITHOUT A RPA NUMBER WILL BE REFUSED This limited warranty is in lieu of any other warranties express or implied including any im...

Page 26: ...26...

Reviews: