background image

MODELS LDO33 & LDO50 

BELT-DRIVE OR CHAIN-DRIVE 

GARAGE DOOR OPERATORS

INSTALLATION INSTRUCTIONS 

For Sectional and Jamb Type Doors

IMPORTANT SAFETY NOTES

Please  read  the  instructions  carefully! This  garage  door 

operator is designed to provide safe and reliable service 

if installed and tested as described in these instructions. 

A  garage  door  is  the  largest  mechanical  appliance  in  a 

residence. Care must be taken to prevent injury or death 

during  installation  and  operation  of  the  garage  door  and 

garage door operator.

1  Check the Door Balance

1  From outside the garage, slowly open the door all the 

way,  and  then  close  it  all  the  way.  Notice  if  there  is 

any binding, sticking or rubbing. The door should move 

smoothly in both directions.

2  Raise  the  garage  door  about  halfway  up.  Carefully 

release the door and see if the door balances. It should 

stay in place. Close the door.

� 

IMPORTANT:

 If the garage door is unbalanced or 

the door travel isn’t smooth, have a qualified garage 
door professional adjust or repair the door.

2  Attach the Rail to the Operator

1  Place  the  operator  head  on  the  garage  floor  with 

cardboard underneath it to protect the finish.

� 

NOTE:

  To  prevent  upsetting  the  pre-adjusted  door 

limits in the operator, keep the trolley at the same place 
on the rail until the sprocket is on the drive shaft.

2  Align the rail over the center of the operator head.
3  Be sure the flat on the sprocket lines up with the flat on 

the drive shaft.

4  Slide the sprocket onto the shaft.
5  Attach the rail to the operator head by installing four 

¼-20 x ¾” bolts.

6  Tighten the four bolts in the order shown with a 7/16” 

socket.

3  Locate the Header Bracket Position

1  Check whether door is a sectional or one-piece jamb type

Note  the  differences  in  mounting  header  bracket, 

door arm assembly and hanging the operator.

2  Close the door.
3  From  inside  the  garage,  use  a  pencil  to  mark  the 

vertical centerline of the door on the header wall and 

on the top panel of a sectional door or on the top edge 

of a jamb door.

4  Examine the area above the center of the door on the 

door header wall for a header bracket mounting location.

5  Open the door to the high-rise point (the point where 

the top edge of the door is highest above the floor) and 

measure the distance to the floor.

6  Close the door and use a pencil to mark the header 

wall  1”  above  (sectional)  or  7”  above  (jamb)  the 

measured high-rise point.

� 

NOTE:

  In  some  installations,  the  header  bracket 

location will be higher than the door header. This will 

require adding a 2x4 (or larger) cross piece to the wall 

studs  to  provide  a  mounting  location  for  the  header 

bracket.  Use  lag  screws  (not  supplied)  to  attach  the 
2x4 to the studs.

7  On  sectional  doors  with  low  headroom,  the  header 

bracket can be attached to the ceiling up to 6” back 

from the header wall (see next step).

4  Install the Header Bracket

Attaching the Header Bracket to the Wall

1  Hold  the  header  bracket  on  the  center  line  drawn 

above the door with the bottom edge of the bracket on 

the line marked above the high-rise point.

2  Use a pencil to mark the two bracket holes.
3  Drill two 3/16” pilot holes about 2” deep.
4  Use a ½” socket to fasten the bracket with two 5/16” x 2” 

lag screws.

Attaching the Header Bracket to the Ceiling 

� 

NOTE:

 On a finished ceiling, be sure there is a joist 

to  fasten  to  under  the  sheetrock  where  the  header 

bracket will be located (use a stud finder). If there is 

none, install a 2x4 cross piece between the two closest 
joists to fasten the header bracket onto.

1  Extend the center line drawn on the header wall along 

the ceiling.

2  Hold the bracket on the center line with the edge of the 

bracket no further than 6” from the header wall.

3  Use a pencil to mark the two bracket holes.
4  Drill two 3/16” pilot holes about 2” deep.
5  Use  a  ½”  socket  to  fasten  the  bracket  with  two 

5/16” x 2” lag screws.

5  Connect the Rail to the Header Bracket

1  Place assembled operator on the empty carton on the 

floor with rail towards the door.

2  Insert the end of the rail into header bracket.
3  Insert  the  5/16”  x  2-3/8”  clevis  pin  through  header 

bracket and rail.

4  Secure the clevis pin with the hitch pin.

6  Hang the Operator

Installation requirements vary with garage construction. 

Hanging  brackets  should  be  angled  to  provide  rigid 

support. 

Hanging material is not provided. Angle iron 

and lag screws are recommended. 

DO NOT USE NAILS. 

Following are typical operator hanging methods. Certain 

installations will require improvised methods.

1  Raise the operator head and set it on top of a stepladder 

(use extra spacers on top of ladder if it isn’t tall enough).

2  SECTIONAL DOORS: Carefully open the door to the 

full up position. Lay a 2x4 across the top section of the 

door as a spacer. Adjust the operator height until the rail 

touches the spacer. The rail should be close to level.

  JAMB DOORS: Carefully open the door to the high-

rise point. Adjust the operator height until the rail is 2” 

above the door high-rise point. The rail should angle 

up towards the header wall.

3  Center the operator head and rail with the centerline 

mark on the top of the door.

4  For  finished  ceilings  only:  An  angle  iron  cross  piece 

between the two closest joists above the operator will be 

required. Mark mounting hole locations, drill pilot holes 

and attach the piece with two lag screws (not supplied).

5  Measure  the  distance  from  each  of  the  operator’s 

hanging tabs to the ceiling joists or angle iron cross piece.

6  Cut two angle iron pieces to the required lengths for 

hanging brackets. Bend brackets if required.

  • For unfinished ceilings: Hold each bracket in place 

and use a pencil to mark the locations where they will 

be attached to the joists, drill pilot holes and attach the 

pieces with two lag screws (not supplied).

  • For finished ceilings with an angle iron cross piece: 

Attach  the  two  hanging  brackets  to  the  cross  piece 

with two bolts and two keps nuts (not supplied).

7  Attach operator to hanging brackets using two 5/16-18 x 

1” hex bolts and two 5/16-18 keps nuts (supplied). Insert 

bolts from the inside of hanger brackets with the nuts on 

the outside of the operator. Tighten nuts with a ½” socket.

8  Tighten all hanging hardware.
9  Open and close the door manually. The door should 

clear the rail by at least 1”.

10 Attach  the  trolley’s  release  lever  to  the  red  release 

handle with the cord supplied so the handle is at least 

6 feet from the floor. Cut off any excess cord.

11 Swing open the light cover to access the lamp socket. 

Install a 100 watt maximum rough service in the lamp 

socket. Swing the light cover closed, snapping it shut.

IMPORTANT INSTALLATION SAFETY INSTRUCTIONS

  WARNING 

TO REDUCE THE RISK OF SEVERE INJURY OR DEATH TO PERSONS, REVIEW 

THESE INSTALLATION SAFETY STEPS BEFORE PROCEEDING

1  READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS.
2  Install only on a properly balanced garage door. 

An improperly balanced door could result in severe 

injury or death.

 Repairs to cables, spring assemblies, and other hardware must be made by a qualified 

service person before installing the operator.

3  Disable all locks and remove all ropes connected to the garage door before installing the operator. 

Ropes connected to a garage door can cause entanglement and death.

4  If  possible,  install  door  operator  7  feet  or  more  above  the  floor  with  the  manual  release  handle 

mounted 6 feet above the floor.

5  Do not connect the operator to the power source until instructed to do so.
6  Locate the wall station within sight of the door at a minimum height of 5 feet so that small children 

cannot reach it. Locate the wall station away from all moving parts of the door.

7  Install the User Safety Label on the wall adjacent to the wall station.
8  Upon completion of the installation, the door must reverse when it comes in contact with a 1-1/2” high 

object (or a 2x4 laid flat at the center of the door) on the floor and when the infrared safety beam is 
blocked.

9  Do not wear watches, rings or loose clothing while installing or servicing an operator. Jewelry or 

loose clothing can be caught in the mechanism of the garage door or the operator.

10 DISCONNECT THE  ELECTRIC  POWER  FROM THE  GARAGE  DOOR  OPERATOR  BEFORE  MAKING 

ANY REPAIRS OR REMOVING THE COVER.

7  Install the Wall Station

� 

NOTE:

  22  AWG  2-conductor  wall  station  and  safety 

beam wire is supplied with the operator, Use this wire 
or  the  installation’s  pre-wiring.  For  additional  wire, 
contact  Linear  for  information  regarding  the  24-pack 
Model HAE00009 wire and wire clip kit.

� 

UL NOTE:

 All low voltage Class 2 cable used with this 

operator must be UL Listed Type CL2, CL2P, CL2R, or 
CL2X or other cable with equivalent or better electrical, 
mechanical, and flammability ratings.

1  Strip back ½” of insulation and connect a wire to each 

of the two terminals on the back of the wall station.

2  Use the screws provided to mount the wall station near 

an access door at a minimum height of five feet. 

SEE 

IMPORTANT WARNING ABOVE!

3  For  non-prewired  installations,  route  the  wire  to  the 

back  of  the  operator.  Use  insulated  staples  (not 

supplied)  to  secure  the  wire.  Staples  must  straddle 

both wires to avoid electrical shorts.

4  Cut the wall station wire about 6” longer than needed to 

reach the operator terminals. Strip back ½” of insulation.

5  Connect either wire to the operator’s PUSHBUTTON 

terminal and the other wire to the operator’s COMMON 

terminal. 

6  Apply the User Safety Instruction Label to the wall next 

to  the  wall  station.  Use  staples  or  tacks  to  help  the 

label remain in place over time.

� 

IMPORTANT!

 DO NOT PLUG THE OPERATOR IN AT 

THIS TIME! More installation is required.

8  Install the Safety Beam

� 

NOTE: 

The  safety  beam’s  infrared  light  beam  must 

not be obstructed by the door, or by any part of the 
door  hardware.  Use  wooden  spacers  between  the 
beam brackets and wall if necessary to create proper 
clearance.

1  Assemble the two safety beam brackets from the four 

L-shaped  brackets  using  two  ¼-20  x  ¾”  bolts  and 

¼-20 keps nuts (one nut & bolt for each bracket).

2  Position the assembled brackets on each side of the 

door 

so the center line of the safety beam lenses 

will be 6” above the floor. Use the index marks on 

the  brackets  to  make  the  bracket  assemblies  equal 

lengths.  Mark  the  locations  for  the  bracket  mounting 

screws (the brackets can be wall or floor mounted).

� 

NOTE:

 The  safety  beam  receiver  (the  unit  with  two 

indicators)  should  be  located  on  the “shady”  side  of 
the door to prevent sunlight from shining directly into 
the receiver’s lens.

3  Drill  two  3/16”  pilot  holes  for  lag  screws  at  marks. 

Mount the brackets with two ¼” x 1-¼” lag screws and 

tighten  with  a  7/16”  socket  (or  use  proper  concrete 

fasteners if floor mounting).

4  Insert the sender and receiver into the bracket holes 

so the lenses of the units will face each other. Twist the 

units until the spring clips lock into a detent mark on 

the brackets. To protect the units from being bumped 

after  installation,  it  is  recommended  to  mount  the 

sender and receiver inside the brackets as shown. 

 IMPORTANT: 

Be careful to route the safety beam wiring 

away from any moving parts of the door or operator.

5  For  non-prewired  installations,  route  the  wires  from 

the  sender  and  receiver,  up  the  wall  above  the  door 

hardware, then over to the center of the door, then along 

the top of the rail (or ceiling), and back to the operator 

head.  Cut  the  wires  about  6”  longer  than  needed  to 

reach the operator terminals. Strip back ½” of insulation 

from the ends of the wires.

6  For  non-prewired  installations,  secure  all  the  wires 

to  the  wall  and  ceiling  with  insulated  staples  (not 

supplied). Staples must straddle both wires to prevent 

shorts. Secure the wire to the top of the rail with wire 

clips (supplied).

7  At the operator, twist one wire from each pair together, 

then twist the other wire from each pair together.

8  Attach  either  twisted  connection  to  the  operator’s 

BEAM terminal. Connect the other twisted connection 

to the operator’s COMMON terminal.

9  Install the Door Bracket and Door Arm

SECTIONAL DOORS
1
  Fully close the door. Hold the door bracket against the 

inside of the door’s top panel. Align the top edge of the 

bracket 2” to 4” below the top edge of the door; or, if 

there is a structural support across the top of the door, 

place  the  top  edge  of  the  bracket  directly  below  the 

support. Align the vertical centerline drawn on the door 

with the center of the bracket. See the figure for details. 

Mark the left and right holes of the bracket.

2  Drill ¼” holes at marks and insert two ¼-20 x 2” carriage 

bolts (not supplied) from outside of door through the 

door bracket.

3  Secure  door  bracket  with  two  ¼-20  keps  nuts  (not 

supplied). Tighten with a 7/16” socket.

4  Slide the 5/16” x 1-3/8” clevis pin through one hole on 

door bracket; then the single hole on the curved door arm; 
then through the other hole on the door bracket. Secure 
the clevis pin with the hitch pin.

5  Insert the single hole end of the straight door arm into 

the slot in the trolley. Slide the 1-1/8” clevis pin through 

the hole and secure it with a hitch pin.

6  Flip the trolley release lever to disconnect the trolley.
7  Rotate  the  curved  door  arm  upward  to  meet  the 

straight  door  arm  connected  to  the  trolley.  Align  the 

two door arms so that the holes in both arms overlap.

� 

NOTE: The straight door arm should be slightly angled 
toward the operator head. 

JAMB DOORS
1  
With the door fully open, hold the door bracket on the 

vertical centerline drawn on top edge of the door. Use a 

pencil to mark the four mounting holes of the bracket.

2  Drill ¼” holes at marks and fasten the bracket with two 

5/16” x 2” lag screws to the top of the door.

3  Slide the 5/16” x 1-3/8” clevis pin through one hole on 

door  bracket;  then  the  single  hole  on  the  straight  door 
arm;  then  through  the  other  hole  on  the  door  bracket. 
Secure the clevis pin with the hitch pin.

4  Insert the single hole end of the curved door arm into 

the slot in the trolley. Slide the 1-1/8” clevis pin through 

the hole and secure it with a hitch pin.

5  Flip the trolley release lever to disconnect the trolley.
6  Rotate  the  straight  door  arm  upward  to  meet  the 

curved door arm connected to the trolley. Align the two 

door arms so that the holes in both arms overlap.

CONNECTING DOOR ARMS
1
  Line up door arms until trolley is positioned as shown. 

Connect the arms together using two 5/16-18 x 1” bolts 

inserted  in  the  highest  and  lowest  matching  holes, 

secure the bolts with two 5/16” keps nuts, tighten with 

a ½” socket.

10  Connect the Operator to Power Source

Cord and Outlet Connection

The  operator  should  be  connected  to  a  grounded 

receptacle  on  the  ceiling  or  near  the  operator  head.  If 

none is available which will accept the grounded operator 

plug, one should be installed by a qualified electrician. 

Do 

not use an extension cord.

1  Plug the operator into a grounded receptacle.
2  When the operator is plugged in, a click should sound 

in  the  operator  and  the  light  should  turn  on.  If  light 

does  not  turn  on,  check  the  power  source  and  light 

bulb.

Permanent Wiring

SOME  LOCAL  ELECTRICAL  CODES  REQUIRE 

PERMANENT  WIRING  BETWEEN  THE  OPERATOR 

AND THE  POWER  SOURCE THROUGH  A  CONDUIT. 

IT IS RECOMMENDED THAT YOU HAVE A LICENSED 

ELECTRICAL CONTRACTOR FOLLOW THESE STEPS 

ONLY IF PERMANENT WIRING IS REQUIRED.

1  BE SURE POWER CORD IS UNPLUGGED.
2
  Cut  the  power  cord  about  2”  above  the  strain  relief 

bushing on the operator.

3  Remove  the  four  side  screws  and  bottom  cover  of 

operator.

4  Use  pliers  to  remove  the  strain  relief  bushing  and 

discard the bushing.

5  Remove the outer insulation from the power cord and 

strip the white, black, and green wire insulation back 

about ½”.

6  Pull  white  (neutral),  black  (hot)  and  green  (ground) 

wires through conduit.

7  Connect  the  conduit  to  the  operator  with  the 

appropriate termination.

8  Use wire nuts (not supplied) to connect the wires to the 

matching color wires inside operator head.

9  Secure  the  wires  away  from  all  moving  parts  with  a 

zip-tie as shown in the figure.

10 Replace the operator cover and the four side screws.
11 Connect  the  conduit  wires  to  the  power  source  at 

junction box.

12 When power is applied to the operator, a click should 

sound  and  the  light  should  turn  on.  If  the  light  does 

not turn on, check the power source, wiring, and light 

bulb.

  WARNING 

Children operating or playing with a garage door operator can injure themselves or others. The garage 

door could cause serious injury or death. Do not allow children to operate the remote control(s) or 

the wall station. Install the wall station out of reach of children and away from all moving parts of 

the door. The door must be clearly visible from the wall station. A moving garage door could injure 

someone under it. Only activate the door when it is properly adjusted, when it can be seen clearly 

and when there are no obstructions to the door travel.

  WARNING 

Persons,  particularly  children,  could  be  killed 

by  a  closing  garage  door  without  a  properly 

installed  and  adjusted  safety  beam  optical 

obstacle sensing system.

  WARNING 

To  protect  small  children,  do  not  install  the 

safety beam higher or lower than instructed.

THE DOOR SHOULD
BALANCE WITHOUT
GOING UP OR DOWN

CHECKING THE DOOR BALANCE

LINE UP THE RAIL OVER THE DRIVE SHAFT

ON TOP OF THE OPERATOR HEAD

ALIGNING THE RAIL

BE SURE THE FLAT ON THE SPROCKET

LINES UP WITH THE FLAT ON THE DRIVE SHAFT

CHAIN DRIVE

BELT DRIVE

TIGHTEN THE RAIL-TO-HEAD BOLTS IN THIS ORDER

1

2

3

4

INSTALL FOUR 1/4-20 x 3/4"
RAIL-TO-HEAD BOLTS

USING A 7/16" SOCKET

PULL THE CHAIN OR BELT
AWAY FROM THE RAIL TO

FIT THE SOCKET ON THE

FRONT  BOLTS 

ATTACHING THE RAIL

MATING THE SPROCKET AND SHAFT

TABS FIT INTO SLOTS

SLIDE THE SPROCKET
INTO THE SHAFT

CHAIN DRIVE

BELT DRIVE

MARK THE CENTERLINE
OF THE DOOR ON THE
HEADER AND THE TOP

DOOR PANEL

MARKING THE CENTERLINE

IF JAMB DOOR 

MARK THE TOP 
EDGE OF THE DOOR

HIGH-RISE 
POINT

HIGH-RISE 

POINT

MEASURE

DISTANCE
TO FLOOR

CLOSE DOOR
AND MARK

HEADER 7"

ABOVE

MARK HEADER
1" ABOVE 

SECTIONAL DOOR

JAMB DOOR

MARKING ABOVE THE HIGH-RISE POINT

CENTERLINE OF DOOR

1 INCH (SECTIONAL)

2 INCHES (JAMB)

HIGH-RISE POINT
OF DOOR

ATTACH HEADER

BRACKET WITH 
TWO 5/16" x 2" 
LAG SCREWS

1/2" SOCKET

ATTACHING THE HEADER BRACKET

DOOR
HEADER
WALL

NO MORE

THAN 6 INCHES

CENTERLINE OF DOOR

FOR LOW HEADROOM SECTIONAL

DOOR INSTALLATIONS ONLY

ATTACHING THE HEADER BRACKET TO THE CEILING

INSERT HITCH PIN
INTO CLEVIS PIN

2-3/8" LONG

CLEVIS PIN

CONNECTING THE RAIL

PREPARING TO HANG THE OPERATOR

TYPICAL HANGING BRACKET
ASSEMBLY USING A CROSSPIECE

TYPICAL HANGING BRACKETS
SCREWED DIRECTLY TO JOISTS

HANGING BRACKET OPTIONS

PLACE A 2x4 SPACER 
BETWEEN THE DOOR AND RAIL

ADJUST HEIGHT 
AS REQUIRED

2" MAXIMUM BETWEEN
HIGH-RISE POINT AND 
BOTTOM OF RAIL

ADJUSTING OPERATOR HEIGHT

SECTIONAL DOOR

JAMB DOOR

HANG OPERATOR
WITH TWO 5/16-18 x 1"
BOLTS AND NUTS

HANGING THE OPERATOR

CONNECT PUSHBUTTON WIRES
TO WALL STATION'S TERMINALS

MOUNT WALL STATION
AT LEAST 5 FEET ABOVE
THE FLOOR LEVEL

CONNECTING AND LOCATING THE WALL STATION

WIRES TO
WALL STATION

CONNECT WALL STATION WIRES
 TO PUSHBUTTON AND COMMON

  TERMINALS (EITHER WIRE
   TO EITHER TERMINAL)

CONNECTING THE WIRES TO OPERATOR

ASSEMBLE BRACKETS
WITH 1/4-20 x 3/4" BOLTS
AND KEPS NUTS

ASSEMBLING THE BRACKETS

SAFETY BEAM BRACKET OPTIONS

WALL MOUNTING

FLOOR MOUNTING

BRACKET
INDEX
MARKS

LOCATE THE SAFETY BEAM
BRACKETS SO THE BEAM

CENTERLINE IS 6" ABOVE THE FLOOR

MARKING THE CORRECT BEAM BRACKET HEIGHT

INSERT UNIT
INTO BRACKET

TWIST UNIT TO
LOCK INTO BRACKET

INSTALLING THE BEAMS

SPRING CLIP LACTHES
INTO DETENT MARKS
TO HOLD UNIT'S POSITION

PRE-ADJUSTING THE BEAMS

ADJUST UNITS SO
LENSES POINT TOWARD
EACH OTHER

PUSHBUTTON

WIRES

CONNECT SAFETY BEAM WIRES
 TO COMMON AND BEAM

   TERMINALS (EITHER WIRE

     TO EITHER TERMINAL)

BEAM
WIRES

CONNECTING THE BEAM WIRES

STRAIGHT DOOR ARM (SECTIONAL)
CURVED DOOR ARM  (JAMB)

SLIDE IN THE
1-1/8" CLEVIS PIN

INSTALL THE
HITCH PIN

CONNECTING THE DOOR ARM TO THE TROLLEY

TROLLEY

INSTALLING THE DOOR BRACKET (SECTIONAL DOOR)

DOOR

STRUCTURAL

SUPPORT

ALIGN THE DOOR BRACKET 

ON THE CENTERLINE 2" TO 4"

BELOW THE TOP EDGE

OF THE DOOR, OR DIRECTLY

BELOW ANY DOOR

STRUCTURAL SUPPORT

DRILL TWO 1/4" PILOT HOLES
USE TWO 1/4-20 x 2" CARRIAGE BOLTS AND

NUTS (NOT SUPPLIED) TO ATTACH THE DOOR BRACKET

DOOR

BRACKET

CAUTION! LIGHTWEIGHT SECTIONAL DOORS

NOT DESIGNED FOR USE WITH A GARAGE
DOOR OPENER MUST BE EQUIPPED WITH A

DOOR REINFORCEMENT KIT (CHECK WITH
THE GARAGE DOOR MANUFACTURER)

LINE UP DOOR ARMS UNTIL TROLLEY 
IS POSITIONED AS SHOWN

CONNECT ARMS WITH

TWO 5/16-18 x 1" BOLTS
IN THE HIGHEST AND
LOWEST MATCHING HOLES

CONNECTING THE DOOR ARMS

4" TO 6"

2" TO 4"

APPROXIMATELY

18"

JAMB DOOR

SECTIONAL DOOR

ALIGN CENTER OF 
DOOR BRACKET 

WITH  CENTERLINE 
DRAWN ON DOOR

INSTALLING THE DOOR BRACKET (JAMB DOOR)

USE TWO
5/16" X 2"
LAG SCREWS 

TO FASTEN 
BRACKET TO
DOOR

  WARNING 

This type of warning note is used to indicate 

possible  mechanical  hazards  that  may  cause 

serious injuries or death.

  CAUTION 

This type of warning note is used to indicate 

the possibility of damage to the garage door or 

garage door operator.

  WARNING 

This  type  of  warning  note  is  used  to  indicate 

possible  electrical  shock  hazards  that  may 

cause serious injuries or death.

THE FOLLOWING FORMATS ARE USED FOR 

SAFETY NOTES IN THESE INSTRUCTIONS.

  WARNING 

To  prevent  electrocution  or  fire,  installation 

and  wiring  must  be  in  compliance  with  local 

electrical and building codes.

  WARNING 

To  reduce  the  risk  of  electric  shock,  this 

operator  has  a  grounding  pin.  This  plug  will 

only fit into a grounding type outlet. If the plug 

doesn’t fit into the outlet, contact a qualified 

electrician to install the proper outlet. Do not 

change the plug in any way.

PLUG OPERATOR
INTO GROUNDED

OUTLET

CEILING
OUTLET

POWERING THE OPERATOR

PRINTER’S INSTRUCTIONS:

INSTR,INSTL,LDO W/MCT3; LINEAR P/N: 223709 C; INK: BLACK; MATERIAL: 20# MEAD BOND; SIZE: 17.000” x 22.000”; FOLDING: 2-FOLDS VERTICAL, 1-FOLD HORIZONTAL, FINISH 8.500” X 5.500” WITH LOGO SHOWING; SCALE: 1-1; SIDE 1 OF 2 

BE SURE THE POWER

CORD IS UNPLUGGED!!

CUT THE CORD ABOUT
2" ABOVE THE STRAIN
RELIEF BUSHING

REMOVING THE POWER CORD

FOR PERMANENT WIRING ONLY!

REMOVE STRAIN
RELIEF BUSHING

WITH PLIERS

REMOVING THE BUSHING

FOR PERMANENT WIRING ONLY!

CONDUIT

WIRE
NUTS

HARDWIRING THE OPERATOR

CONNECT CONDUIT

WIRING TO OPERATOR
WIRING WITH
WIRE NUTS

GREEN - GROUND

WHITE - NEUTRAL
BLACK - HOT

FOR PERMANENT WIRING ONLY!

ROUTE WIRE

THROUGH
SLOT IN 

CASE

MOUNTING THE WALL STATION

USE WOOD SCREWS

WHEN MOUNTING
DIRECTLY TO WALL 

USE MACHINE SCREWS

WHEN MOUNTING TO

A SINGLE-GANG BOX

PUT HOLE

PLUGS IN
TO HIDE

SCREWS

SECTIONAL DOOR

JAMB DOOR

STRAIGHT

DOOR

ARM

CURVED

DOOR

ARM

CONNECT

SINGLE-HOLE

END OF

DOOR ARM

CONNECTING THE DOOR ARM TO THE DOOR BRACKET

INSTALL

HITCH PIN

1-3/8"

CLEVIS

PIN

INSTALL

HITCH PIN

1-3/8"

CLEVIS

PIN

  CAUTION 

- BELT RAILS HBT7 ONLY! -

TURN THE OPERATOR’S OPEN LIMIT 4 TURNS IN 

THE DOWN DIRECTION BEFORE OPERATING UNIT.

LINEAR LLC

(760) 438-7000

USA & Canada (800) 835-5666 & (800) 421-1587

Toll Free FAX (800) 468-1340

www.linearcorp.com

Reviews: