background image

4

Accessory Overview

PBUS Accessories

Several compatible accessories are available to connect to the AE-2000’s 
three 6-wire communications “PBUS” inputs. Up to six PBUS accessories 
can be used with each AE-2000 unit.

AM-RRR Remote Radio Receiver

For wireless transmitters, connect the Model AM-
RRR high-gain superheterodyne UHF receiver. The 
receiver is housed in a weather-resistant enclosure 
and can be mounted indoors or outdoors. Gaskets 
and a weather-tight wiring strain relief seal the unit 
from the elements.

AM-RPR Radio Proximity Receiver

The Model AM-RPR functions as a remote device 
that supplies localized radio reception for the 
AE-2000 In a typical installation, the AM-RPR 
would be mounted in a plastic single-gang electrical 
box next to the controlled opening. When the user 
requires access, their transmitter must be activated 
within three inches of the AM-RPR faceplate.

AM-KP Exterior Keypad

The Model AM-KP is housed in a rugged cast 
aluminum enclosure designed for exterior 
installations. The die-cast keys have bright, 
easy-to-read yellow graphics. The keypad can 
be mounted to a pedestal or directly to a wall. 
A keylock secures the keypad to the mounting 
backplate.

AM-KPI Interior Keypad

The Model AM-KPI keypad is housed in a rugged, 
plastic enclosure designed to be mounted indoors 
in a standard single-gang electrical box. Tamper 
resistant screws secure the keypad to its mounting 
plate. The die-cast keys have bright, easy-to-read 
yellow graphics and is illuminated with white 
LEDs.The keypad is supplied with a satin-chrome 
bezel and three interchangeable colored bezels 
(white, ivory, & bronze) to customize the keypad 
appearance for the installation.

AM-CRI Card Reader Interface

The Model AM-CRI expands the standard two 
AE-2000 Wiegand inputs by supporting one or 
two additional 26-bit Wiegand input devices per 
AM-CRI interfaces used.

Wiegand Accessories

Two Linear accessories are available to connect WIEGAND format 
devices to the AE-2000. Most other manufacturer’s 26, 30 & 31-bit 
WIEGAND output devices can also be used with the AE-2000.

WOR Wiegand Output Radio Receiver

For block-coded Linear wireless transmitters, 
connect the Model WOR high-gain superheterodyne 
UHF receiver. The receiver is housed in a weather-
resistant enclosure and can be mounted indoors or 
outdoors. Gaskets and a weather-tight wiring strain 
relief seal the unit from the elements.

AM-PR Proximity Reader

The Model AM-PR is a radio-based reader that 
works with either proximity tags (Model AM-PT) 
or proximity cards (Model AM-PC), both of which 
are slotted to attach to key rings. Upon reading a 
user’s tag or card, it transmits the entry data via a 
Wiegand output to the AE-2000. An integral LED 
confi rms to the user that access is granted.

220231 B     IMAGE 4

AM-RRR

*

5

6

7

8

9

0

#

1

2

3

4

AM-KP

AM-KPI

AM-RPR

AM-PR

AM-CRI

*

AM-

RRR

R

EMOTE

R

ADIO

R

ECEIVE

R

EXA-2000

R

EMOTE

R

ADIO

ANTENNA

AM-

R

P

R

R

ADIO

P

R

OXIMITY

R

ECEIVE

R

AM-KP

EXTE

R

IO

R

KEYPAD

AM-KPI

INTE

R

IO

R

KEYPAD

AM-C

R

I

CA

R

D

R

EADE

R

INTE

R

FACE

AM-P

R

P

R

OXIMITY

R

EADE

R

PBU

S

ACCE

SS

O

R

IE

S

WIEGAND

ACCE

SS

O

R

IE

S

AE-2000

TELEPHONE ENT

R

Y

&

 ACCE

SS

 CONT

R

OL

S

Y

S

TEM

AM-WO

R

WIE

G

AND

OUTPUT

R

ECEIVE

R

WOR

Summary of Contents for AE-2000

Page 1: ...USA Canada 800 421 1587 800 392 0123 760 438 7000 Toll Free FAX 800 468 1340 www linearcorp com AE 2000 Telephone Entry Access Control System Installation Instructions...

Page 2: ...ectory number for the desired resident Upon selecting the directory number the AE 2000 will automatically dial the resident s telephone number and establish two way voice communication between the vis...

Page 3: ...netic locks automatic doors barrier gates and automatic sliding gates The relay outputs can also be used as specialty outputs for alarm contact shunting operator obstacle triggering and alarm activati...

Page 4: ...yellow graphics and is illuminated with white LEDs The keypad is supplied with a satin chrome bezel and three interchangeable colored bezels white ivory bronze to customize the keypad appearance for...

Page 5: ...NECTOR CAMERA CONNECTOR HIDDEN OPTIONAL CAMERA PBUS TERMINALS NETWORK TERMINALS AM MIO INTERFACE TELEPHONE INTERFACE CONNECTOR TAMPER MAGNET SYSTEM RESTART BUTTON RESIDENT S VOICE VOLUME ADJUSTMENT FO...

Page 6: ...RELAY CHANNEL C TERMINALS RELAY CHANNEL D TERMINALS RELAY RATING 3 AMPS 30 VOLTS AC DC MAXIMUM EARTH GROUND STAKE GROUND STUD WIEGAND DEVICE LED2 HOLD LED1 DAT 1 DAT 0 GND PWR WIEGAND DEVICE LED2 HOLD...

Page 7: ...rom the AE 2000 NEVER MOUNT THE UNIT DIRECTLYTO A MOVING DOOR OR GATE Gate Installations If the AE 2000 is used to control a gate operator connected to a vehicular gate the unit MUST be mounted AT LEA...

Page 8: ...move the green ground wire lug from the stud 3 Remove the two bottom circuit board mounting plate nuts 4 Loosen the two top circuit board mounting plate nuts 5 Carefully lift up on the mounting plate...

Page 9: ...edestal Mounting The cabinet can be mounted on a gooseneck pedestal Linear manufacturers two pedestals Model GNC 1 is for surface mounting with concrete fasteners Model GNB 1 is for burial mounting Wh...

Page 10: ...s are typically used with push bars loop sensors or pushbuttons 1 Install the pushbutton or device to signal an exit request 2 Route two wires from the device to the AE 2000 3 Connect the device s nor...

Page 11: ...Battery positive to the AE 2000 DC terminal and the negative to the DC terminal NOTE The AE 2000 does not supply battery charging current An external battery charger will be required to maintain the b...

Page 12: ...metal surface using a 3 8 hole Two other models of antennas are compatible with the AE 2000 The Model EXA 1000 is a non directional antenna The Model EXA 2000 is a directional antenna used in install...

Page 13: ...ammed output relay will activate Postal Lock Installation 1 After opening the cabinet re lock the left cabinet lock to provide clearance to remove the postal lock switch plate 2 Remove the four locknu...

Page 14: ...variety of 26 30 and 31 bit Wiegand output accessories The Wiegand format is a common standard for access control equipment A typical application would be to add swipe card or proximity readers to the...

Page 15: ...nit 3 Route 3 conductor shielded cable from the hub unit to one of the other units Repeat this step to connect the hub unit to each of the other units 4 Connect the 3 conductor cable to each unit s NE...

Page 16: ...ring operation When calling for technical assistance Linear s Technical Services Department may ask the installer to use these components to diagnose the system On board Indicators 17 LED indicators a...

Page 17: ...or up to ten system settings can be controlled in Program Mode By viewing the STATUS PROGRAM display and using the UP DOWN and ENTER pushbuttons the various options can be set for each of the system s...

Page 18: ...ill dial the resident s telephone number to establish 2 way communications NOTE The resident s telephone number will never be displayed to the visitor If the resident is using the telephone at the sam...

Page 19: ...Form C 3 Amps 30 Volts maximum Inputs Four normally closed door sense inputs Four normally open exit request inputs Two WIEGAND reader inputs Three PBUS inputs Network Three wire network RADIO Frequen...

Page 20: ...interfering devices to determine the source of the interference The antenna or the interfering device may need to be relocated 4 Use Model FT 1 to check for interference Linear Limited Warranty This L...