Telephone Wiring

For telephone entry and programming, the AE-2000 connects to a 
standard telephone line. 

Important Telephone Wiring Tips

• 

DO NOT ROUTE TELEPHONE AND AC WIRIN

G

 INSIDE THE 

SAME CONDUIT

.

 Route all telephone wires inside a dedicated 

conduit that is at least six inches away from any AC line wiring.

•  All telephone wiring must be made on the “building” side of the 

telephone company’s demarcation device (the terminal block 
where the telephone line connects to the building).

•  If any security system or personal alert system at the installation is 

connected to the telephone line, be sure that it is connected to the 
line ahead of the AE-2000 using a RJ-31X or RJ-38X interface.

•  Use only high-quality telephone wire. All telephone wire should be 

twisted-pair with a minimum size of 24 AWG.

Typical Telephone Wiring

1A. If using the AE-2000 modular connector for the telephone 

connection, connect a double-ended modular cable between the 
AE-2000’s 

PHONE

 jack and the modular telephone jack wired to 

the installation’s telephone line.

1B. If using the AE-2000 terminal block for the telephone connection, 

connect the “ring” wire (usually red) to the 

RIN

G

 terminal, connect 

the “tip” wire (usually green) to the 

TIP

 terminal.

Optional Radio Antenna

If wireless transmitters are going to be used in the system a remote 
antenna must be installed to provide reception for the AE-2000.
A basic antenna kit is supplied with the AE-2000. The kit contains a 
whip antenna, connector, and a 36” length of coax cable. The antenna 
connector should be mounted on a metal surface using a 3/8” hole.
Two other models of antennas are compatible with the AE-2000. The 
Model EXA-1000 is a non-directional antenna. The Model EXA-2000 is 
a directional antenna used in installations where transmitted signals are 
desired to be received only in a particular direction.

 NOTE:

 

Up to 50 feet of type 

RG

-5

9

 coax can be used to connect 

the antenna to the AE-2000. Keep the coax as short as possible.

1.  Install the antenna. (See installation instructions if using the 

EXA-1000 or EXA-2000.)

2.  Connect the antenna coax cable to the antenna and route the 

cable to the AE-2000.

3.  Connect the cable to the AE-2000’s 

ANTENNA

 connector.

Receiver Range Control

The AE-2000 has a 

RECEIVER RAN

G

E

 adjustment knob. In some 

installations, it may be necessary to reduce the effective radio range of 
the receiver to limit the distance that transmitters can be used. Reducing 
the radio’s sensitivity may also help in installations where unwanted 
interference is overpowering signals from transmitters.

1.  After the installation and system programming is complete, 

adjust the 

RECEIVER RAN

G

E

 knob to suit the installation. Test 

transmitters from typical locations that they will be used. Set the 
radio range so the receiver can activate from transmitters from 
about 25% more distance than required.

TELEPHONE
TERMINALS

EA

R

TH

R

IN

G

TI

P

TELEPHONE

JACK

TO THE INCOMIN

G

DEDICATED TELEPHONE LINE

CONNECT TELEPHONE
LINE TO TE

R

MINAL

S

 O

R

TELEPHONE JACK

NOTE

:

 THE EA

R

TH

TE

R

MINAL CAN 

B

E

U

S

ED TO CONNECT

TO THE TELEPHONE

GR

OUND 

R

ECEIVE

R

R

AN

G

E

KNO

B

AE-2000

CI

R

CUIT BOA

R

D

CONNECT COAX
TO ANTENNA
CONNECTO

R

R

ECEIVE

R

TE

S

T POINT

OPTIONAL
EXA-

2

000

DI

R

ECTIONAL

ANTENNA

OPTIONAL EXA-1000

OMNI-DI

R

ECTIONAL

ANTENNA

S

UPPLIED

ANTENNA
KIT

CONNECTO

R

3

6" COAX

WHIP
ANTENNA

Summary of Contents for AE-2000

Page 1: ...USA Canada 800 421 1587 800 392 0123 760 438 7000 Toll Free FAX 800 468 1340 www linearcorp com AE 2000 Telephone Entry Access Control System Installation Instructions...

Page 2: ...ectory number for the desired resident Upon selecting the directory number the AE 2000 will automatically dial the resident s telephone number and establish two way voice communication between the vis...

Page 3: ...netic locks automatic doors barrier gates and automatic sliding gates The relay outputs can also be used as specialty outputs for alarm contact shunting operator obstacle triggering and alarm activati...

Page 4: ...yellow graphics and is illuminated with white LEDs The keypad is supplied with a satin chrome bezel and three interchangeable colored bezels white ivory bronze to customize the keypad appearance for...

Page 5: ...NECTOR CAMERA CONNECTOR HIDDEN OPTIONAL CAMERA PBUS TERMINALS NETWORK TERMINALS AM MIO INTERFACE TELEPHONE INTERFACE CONNECTOR TAMPER MAGNET SYSTEM RESTART BUTTON RESIDENT S VOICE VOLUME ADJUSTMENT FO...

Page 6: ...RELAY CHANNEL C TERMINALS RELAY CHANNEL D TERMINALS RELAY RATING 3 AMPS 30 VOLTS AC DC MAXIMUM EARTH GROUND STAKE GROUND STUD WIEGAND DEVICE LED2 HOLD LED1 DAT 1 DAT 0 GND PWR WIEGAND DEVICE LED2 HOLD...

Page 7: ...rom the AE 2000 NEVER MOUNT THE UNIT DIRECTLYTO A MOVING DOOR OR GATE Gate Installations If the AE 2000 is used to control a gate operator connected to a vehicular gate the unit MUST be mounted AT LEA...

Page 8: ...move the green ground wire lug from the stud 3 Remove the two bottom circuit board mounting plate nuts 4 Loosen the two top circuit board mounting plate nuts 5 Carefully lift up on the mounting plate...

Page 9: ...edestal Mounting The cabinet can be mounted on a gooseneck pedestal Linear manufacturers two pedestals Model GNC 1 is for surface mounting with concrete fasteners Model GNB 1 is for burial mounting Wh...

Page 10: ...s are typically used with push bars loop sensors or pushbuttons 1 Install the pushbutton or device to signal an exit request 2 Route two wires from the device to the AE 2000 3 Connect the device s nor...

Page 11: ...Battery positive to the AE 2000 DC terminal and the negative to the DC terminal NOTE The AE 2000 does not supply battery charging current An external battery charger will be required to maintain the b...

Page 12: ...metal surface using a 3 8 hole Two other models of antennas are compatible with the AE 2000 The Model EXA 1000 is a non directional antenna The Model EXA 2000 is a directional antenna used in install...

Page 13: ...ammed output relay will activate Postal Lock Installation 1 After opening the cabinet re lock the left cabinet lock to provide clearance to remove the postal lock switch plate 2 Remove the four locknu...

Page 14: ...variety of 26 30 and 31 bit Wiegand output accessories The Wiegand format is a common standard for access control equipment A typical application would be to add swipe card or proximity readers to the...

Page 15: ...nit 3 Route 3 conductor shielded cable from the hub unit to one of the other units Repeat this step to connect the hub unit to each of the other units 4 Connect the 3 conductor cable to each unit s NE...

Page 16: ...ring operation When calling for technical assistance Linear s Technical Services Department may ask the installer to use these components to diagnose the system On board Indicators 17 LED indicators a...

Page 17: ...or up to ten system settings can be controlled in Program Mode By viewing the STATUS PROGRAM display and using the UP DOWN and ENTER pushbuttons the various options can be set for each of the system s...

Page 18: ...ill dial the resident s telephone number to establish 2 way communications NOTE The resident s telephone number will never be displayed to the visitor If the resident is using the telephone at the sam...

Page 19: ...Form C 3 Amps 30 Volts maximum Inputs Four normally closed door sense inputs Four normally open exit request inputs Two WIEGAND reader inputs Three PBUS inputs Network Three wire network RADIO Frequen...

Page 20: ...interfering devices to determine the source of the interference The antenna or the interfering device may need to be relocated 4 Use Model FT 1 to check for interference Linear Limited Warranty This L...

Reviews: