background image

2

Introduction

Example Six Zone Installation

Figure 1. 

8

-OHM

S

PEAKE

RS

ENC-D

RS

KEYPAD

ENC-LIWP

LOCAL INPUT

WALL PLATE

8

-OHM

S

PEAKE

RS

ENC-LIWP

LOCAL INPUT

WALL PLATE

8

-OHM

S

PEAKE

RS

ENC-LIWP

LOCAL INPUT

WALL PLATE

8

-OHM

S

PEAKE

RS

ENC-LIWP

LOCAL INPUT

WALL PLATE

8

-OHM

S

PEAKE

RS

8

-OHM

S

PEAKE

RS

MP3

PLAYE

R

G

AME

B

OX

ENC-P

S

POWE

R

S

UPPLY

ENC-P

S

POWE

R

S

UPPLY

ENC-HU

B

S

Y

S

TEM

HU

B

ENC-HU

B

EXPAN

S

ION

HU

B

HI-POWE

R

 WI

R

E

(16 AW

G

)

S

PEAKE

R

 ZONE

CA

B

LE

S

 (CAT-5)

HU

B

NET

EXPAN

S

ION

CA

B

LE

(CAT-5)

S

OU

R

CE

INPUT

CA

B

LE

S

(CAT-5)

S

PEAKE

R

 WI

R

E

(16 AW

G

)

S

OU

R

CE

OUTUT

CA

B

LE

S

(CAT-5)

ENC-

S

IWP

S

OU

R

CE INPUT

WALL PLATE

ENC-

S

IWP

S

OU

R

CE INPUT

WALL PLATE

ENC-

S

IWP

S

OU

R

CE INPUT

WALL PLATE

ENC-

S

IWP

S

OU

R

CE INPUT

WALL PLATE

CD PLAYE

R

S

ATELLITE 

R

ADIO

COMPUTE

R

S

TE

R

EO

R

ECEIVE

R

ZONE 1

ZONE 

2

ZONE 3

ZONE 4

ZONE 5

ZONE 6

2171-4

I

R

 EMITTE

R

2171-4

I

R

 EMITTE

R

2171-4

I

R

 EMITTE

R

HU

B

NET

EXPAN

S

ION

S

Y

S

TEM

B

A

S

E

S

Y

S

TEM

ENC-D

RS

KEYPAD

ENC-D

RS

KEYPAD

ENC-D

RS

KEYPAD

ENC-D

RS

KEYPAD

ENC-D

RS

KEYPAD

The Encore! Multi-Room Audio Distribution System is an 
expandable system that distributes four analog or digital audio 
sources over Cat-5 cable to four independent speaker zones. Each 
speaker zone features a backlit keypad with an integrated digital 
amplifi er that selects the audio source and controls the volume, 
tone, balance, loudness, and all other functions of the system. The 
system can be expanded with up to eight distribution hubs for a 
total of 32 speaker zones.

Each keypad (Model ENC-DRS) serves as a speaker zone 
controller for the system. Up to four keypads can be connected to 
each hub. Each keypad contains a Class D digital stereo amplifi er 
providing up to 60 watts maximum output power (30 watts per 
channel) and is designed to connect to a pair of 4, 6, or 8-ohm 
speakers.

Source input wall plates (Model ENC-SIWP) serve as primary 
audio source inputs and wire directly to the hub. Up to four source 
input wall plates can be connected to the “primary” or “base” hub.

Local input wall plates (Model ENC-LIWP) serve as a local audio 
source input at each speaker zone. Local input wall plates connect 
directly to the keypad.

The keypads select between the four primary hub audio sources 
from source input wall plates, or from its local audio source 
connected to a local input wall plate. Both input wall plates feature 
a high quality analog-to-digital converter that encodes analog 
source material to a digital audio format for the system. All system 
connections are with Cat-5 cable, the keypads and both types of 
wall plates mount in a single-gang or larger junction boxes.

The system features IR remote control. An infrared repeater system 
monitors the infrared receivers at each keypad and repeats the 
infrared remote control signals to the audio source components 
through infrared emitters connected to the wall plates. IR emitters 
are sold in a 4-pack as Model 2171-4.

Two remote controls are available. The basic remote control 
(Model ENC-REM) is a miniature unit that can select the audio 
source, control the keypad’s volume, and control mute and power. 
The larger learning remote control (Model ENC-LRM) has all of 
the features of the basic remote with the addition of a built-in IR 
code library and IR learning capability allowing it to control virtually 
any audio source component. The learning remote also has macro 
capabilities that allow programming multiple key sequences.

Features

Pure digital audio delivers crystal clear 

• 

sound to all zones with no signal loss
Class D digital amplifi er in each keypad 

• 

providing 60 watts of output power
Four speaker zones expandable to 32 speaker zones

• 

IR receiver built into each keypad, IR emitter 

• 

output on source input wall plates
Cat-5 wiring

• 

Keypads and audio input wall plates mount 

• 

in single-gang junction boxes

Summary of Contents for 2171-4

Page 1: ...USA Canada 800 421 1587 800 392 0123 760 438 7000 Toll Free FAX 800 468 1340 www linearcorp com Multi Room Audio Distribution System Installation Setup Instructions...

Page 2: ...Unplug the unit from the wall outlet before cleaning or polishing it Do not use liquid cleaners aerosol cleaners gasoline or other flammable fluid Clean the exterior of the unit with a slightly damp...

Page 3: ...le head IR Emitter 4 pack 3 Hub and Power Supply Setup 4 Structured Wiring Enclosure 4 Mounting Bracket Installation 4 Hub and Power Supply Installation 4 Zone Pairing 4 Expansion Hub Setup 5 Expansio...

Page 4: ...ENC SIWP serve as primary audio source inputs and wire directly to the hub Up to four source input wall plates can be connected to the primary or base hub Local input wall plates Model ENC LIWP serve...

Page 5: ...urce components from a remote location Selects audio source Adjusts speaker volume and has mute function Remotely controls system power Programmable macros with up to 19 steps each ENC DRSFA SL 4 Scre...

Page 6: ...et cover plate WARNING Do not connect the power supply to the AC line until after the installation is complete Hub and Power Supply Installation The hub and power supply mount to the grid holes in the...

Page 7: ...d OUT connectors until all the hubs are connected Use Cat 5 cables to interconnect the hub sources Each hub has four 4 SOURCE INPUT and four SOURCE OUTPUT Type 110 punch down connectors Start at the f...

Page 8: ...uld be mounted in locations where audio source components will be placed Each source component will have an audio connection to the wall plate using coax or optical cable and an infrared emitter wire...

Page 9: ...110 punch down tool connect the keypad s Cat 5 cable to 4 one of the KEYPAD ZONE terminals on the hub If using the HI POWER hub outputs connect the 2 conductor wire to one of the HI POWER OUTPUT termi...

Page 10: ...L LEFT CHANNEL 1 2 3 4 0db OFF OFF OFF OFF 4db ON OFF ON OFF 8db OFF ON OFF ON 10db ON ON ON ON The clipping indicator will light if the signal level is too high IR Out Connection The local input wall...

Page 11: ...Power To ready the system for testing power must be applied to the hub s Plug all power supply line cords into the outlets that were installed 1 Verify that the 2 POWER indicator is lit on each hub in...

Page 12: ...res This Linear LLC Warranty is in lieu of all other warranties express or implied All products returned for warranty service require a Return Product Authorization Number RPA Contact Linear Technical...

Reviews: