DEMO MANUAL DC1889A

Quick start proceDure

Demonstration circuit 1889A is an easy way to  evaluate the 

performance of the LTM4624EY. Please refer to Figure 1 

for test setup connections and follow the procedure below.  
1. With  power  off,  place  the  jumpers  in  the  follow-ing 

positions for a typical 1.8Vout application:

JP7

JP6

JP4

RUN

MODE

VOUT Select

ON

CCM

1.8V

2. Before connecting input supply, load and meters, pre-

set the input voltage supply to be between 4V to 14V. 

Pre-set the load current to 0A. 

3. With power off, connect the load, input voltage supply 

and meters as shown in Figure 1. 

4. Turn on input power supply. The output voltage meter 

should display the selected output voltage ±2%. 

5. Once the proper output voltage is established, adjust 

the load current within the 0A to 4A range and observe 

the load regulation, efficiency, and other parameters. 

Output voltage ripple should be measured at J6 with a 

BNC cable terminated into 50Ω and an oscilloscope.

6. To  observe  increased  light  load  efficiency  place  the 

MODE pin jumper (JP6) in the DCM position while input 

power is removed. 

7. For optional load transient testing apply an adjustable 

positive pulse signal between IOSTEP CLK and GND 

pins. The pulse amplitude sets the load step current 

amplitude. The pulse width should be short (<1ms) 

and pulse duty cycle should be low (<15%) to limit the 

thermal stress on the load transient circuit. The load 

step current can be monitored with a BNC connected 

to J5 (50mV/A).

+

A

+

A

– 
+

LOAD

0A TO 4A

+

V

+

V

+

V

IN

Figure 1. Test Setup