background image

4

dc2423af

DEMO MANUAL DC2423A

QUICK START PROCEDURE

Demonstration circuit 2423A is easy to set up and evaluate 

the performance of the LTM9100. For the proper setup of 

a high side 48V application using the DC2423A-A, refer to 

Figure 1 and follow the procedure below. The procedure 

for DC2423A-B and/or low side applications are essentially 

the same, but make sure to observe proper polarities and 

connections in steps 3 and 4 for the alternate configura-

tions. Also, for low side applications make sure JP7 (LINE 

MONITOR) is set correctly.
1.  Connect external power supply to V

CC

 and GND.

2.  Connect external power supply to V

L

 and GND, or move 

jumper JP2 to the V

CC

 position.

3.  Connect external power supply from HIGH SIDE INPUT+ 

banana jack to HIGH SIDE INPUT– banana jack.

4.  Connect  external 48V  load  from  HIGH  SIDE  LOAD+ 

banana jack to HIGH SIDE LOAD– banana jack. The 

on-board 330μF load capacitor may be used in addition 

to or as the only load. Connect banana jacks together 

observing the proper polarities.

5.  Turn on V

CC

, V

L

, and 48V supplies.

6.  The LTM9100 can be turned on by moving the EN jumper 

(JP4) to the ON position, or by connecting external 

stimulus between EN and GND with JP4 removed. The 

power good (

PG

) LED will light after the MOSFET is on.

7.  To control the LTM9100 through I

2

C, install the Quick-

Eval System software on a computer with an available 

USB port. The download website is 

www.linear.com/

software

. Connect DC590 or DC2026 between the com-

puter and DC2423A, and open the QuickEval software. 

If already installed, update the software to obtain the 

LTM9100/DC2423A driver.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Reviews: