10
dc1962cf
DEMO MANUAL DC1962C
"Why Am I Off?” Tool
Use the “Why am I Off?” tool in the LTpowerPlay GUI to diagnose the reason a power supply channel is turned off.
The tool can be located in the top right corner of the GUI, above the Register Information tab. Hover your cursor over
this tab to show the tool.
common Demo BoarD operations
Figure 7. "Why Am I Off” Tool in the LTpowerPlay GUI
What Is a Fault Log?
A fault log is a non-volatile record of the power system
leading up to the time of fault. It holds the most recent
monitored values (uptime, voltage, current, temperature)
that can be analyzed to help determine the cause of the
fault. It is a powerful diagnostic feature of each of the
digital power managers on the DC1962C demo board.
Create a Fault and Fault Log
To create a fault log, you must create a fault, as described
in the Creating a Fault on page 8. Select the appropriate
device in the system tree by clicking on the U1 LTC2974
chip. We will proceed to work with the LTC2974 fault log.
aDvanceD Demo BoarD operations
Summary of Contents for DC1962C
Page 19: ...18 dc1962cf DEMO MANUAL DC1962C DC1962C Details Bottom...
Page 23: ...22 dc1962cf DEMO MANUAL DC1962C Schematic Diagram...
Page 24: ...23 dc1962cf DEMO MANUAL DC1962C Schematic Diagram...
Page 25: ...24 dc1962cf DEMO MANUAL DC1962C Schematic Diagram...
Page 26: ...25 dc1962cf DEMO MANUAL DC1962C Schematic Diagram...
Page 27: ...26 dc1962cf DEMO MANUAL DC1962C Schematic Diagram...
Page 28: ...27 dc1962cf DEMO MANUAL DC1962C Schematic Diagram...
Page 29: ...28 dc1962cf DEMO MANUAL DC1962C Schematic Diagram...