background image

2

dc1865af

DEMO MANUAL DC1865A

Quick start proceDure

DC1865A is easy to set up to evaluate the performance 

of the LT3055. Refer to Figure 1 for proper measurement 

equipment setup and follow the procedure below: 
NOTE: Make sure that the input voltage does not exceed 45V.
NOTE: The shutdown jumper JP8 shunt is required to be 

placed in the OFF or ON position for proper operation.
NOTE: Place the output voltage selection jumper JP1-JP7 

at the desired position. 
NOTE: Do not hot-plug the input voltage terminal V

IN

. The 

absolute maximum voltage on V

IN

 is 50V and hot-plugging 

a power supply through wire leads to the demonstration 

circuit can cause the voltage on the extremely low-ESR 

ceramic input capacitor to ring to twice its DC value. In 

order to protect the IC, a higher ESR Aluminum Electro-

lytic capacitor is placed at the input terminals. This may 

protect against some, but not all, input transients due to 

hot-plugging with a power supply. See Application Note 

88 for more details.
NOTE: Connect the power supply (with power off), load, 

and meters as shown in Figure 1.

1. After all connections are made, turn on input power and 

verify that the output voltage according to the output 

voltage selection jumper (JP1-JP7). If the output voltage 

is different from the above values, use the USER option 

and install R7. Select R7 according to the following 

equation: 

   R7 = (V

OUT

/0.6 – 1) • 60.4k

  NOTE:  If  the  output  voltage  is  too  low,  temporarily 

disconnect the load to make sure that the load is not 

set too high.

2. Once the proper output voltage is established, adjust 

the load within the operating range and observe the 

output voltage regulation, 

FAULT1

FAULT2

, PWRGD 

and other parameters.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Summary of Contents for DC1865A

Page 1: ...rporation All other trademarks are the property of their respective owners Performance Summary tion in the data sheet for a detailed calculation Logic fault pins assert low if the LT3055 is in current limit FAULT2 operating below its minimum output current FAULT1 or is in thermal limit both FAULT1 and FAULT2 The die temperature is indicated by the TEMP pin LT3055 optimizes stability and transient ...

Page 2: ... IC a higher ESR Aluminum Electro lytic capacitor is placed at the input terminals This may protect against some but not all input transients due to hot plugging with a power supply See Application Note 88 for more details NOTE Connect the power supply with power off load and meters as shown in Figure 1 1 Afterallconnectionsaremade turnoninputpowerand verify that the output voltage according to th...

Page 3: ...5af DEMO MANUAL DC1865A Quick Start Procedure Figure 1 Proper Measurement Equipment Setup Figure 2 Measuring Input or Output Ripple Downloaded from Arrow com Downloaded from Arrow com Downloaded from Arrow com ...

Page 4: ...AY CRCW0402274KFKED 11 1 R6 Res Chip 442k 0 06W 1 0402 VISHAY CRCW0402442KFKED 12 1 R8 Res Chip 1 00k 0 1W 1 0603 VISHAY CRCW06031K00FKEA 13 1 R9 Res Chip 121k 0 1W 1 0603 VISHAY CRCW0603121KFKEA 14 1 R10 Res Chip 604Ω 0 1W 1 0603 VISHAY CRCW0603604RFKEA 15 3 R11 R13 R14 Res Chip 499k 0 1W 1 0603 VISHAY CRCW0603499KFKEA 16 1 U1 I C Volt Reg DFN 16 4 3 LINEAR TECH LT3055EDE PBF Additional Demo Boar...

Page 5: ... 1 00K 1 0603 C9 0 1nF C9 0 1nF JP1 1 2V JP1 1 2V R2 90 9K 1 R2 90 9K 1 E7 TEMP E7 TEMP E6 IMON E6 IMON R13 499K 1 0603 R13 499K 1 0603 R9 121k 1 0603 R9 121k 1 0603 E4 GND E4 GND R3 121K 1 R3 121K 1 E3 VOUT 500mA E3 VOUT 500mA E5 FAULT1 E5 FAULT1 C8 0 01uF 0603 C8 0 01uF 0603 R7 OPT 0603 R7 OPT 0603 C6 10uF 50V 1210 C6 10uF 50V 1210 R11 499K 1 0603 R11 499K 1 0603 R1 60 4K 1 R1 60 4K 1 JP8 ON OFF...

Page 6: ...CEPT TO THE EXTENT OF THIS INDEMNITY NEITHER PARTY SHALL BE LIABLE TO THE OTHER FOR ANY INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES The user assumes all responsibility and liability for proper and safe handling of the goods Further the user releases LTC from all claims arising from the handling or use of the goods Due to the open construction of the product it is the user s responsibility...

Reviews: