User Manual
English
IR Remote
ARC: Press to enable or disable the ARC function. The ARC LED on the switch will
illuminate when the function is enabled.
Auto/2.1CH/5.1CH/7.1CH: Press to select the different EDID setting. The
corresponding LED will illuminate on the switch.
Auto/Source: Press to select auto switching or manual switching mode
IN1/IN2/IN3/IN4: Press to select the input port. Please note, the switch must be in
manual switching mode
RS-232 Command List
The product can be controlled using the
“Upper Computer” software. This is available
to download at lindy.com from the 38249 Product web page.
Once the switch is connected to a PC using the included 3.5mm to RS-232 cable, open the Upper
Computer software.
Please select the relevant ‘COM’ port, and set the Baud rate to 19200, then press connect.
Once connected, all software will be available to use
The commands for controlling the switch are below:
Baud rate: 19200
Data Width: 8bit
Parity: None
Stop: 1 bit