LB-1000-EDFA
User Manual
APC
mode. APC mode is the preferred mode of operation.
Laser Optical Power
Displays the power of the pump laser
Laser Bias Current
Shows the laser bias current (mA) of the module
Laser Temperature
Shows the laser temperature (°C)
Laser TI
Shows the pump laser TEC current (mA) of the module
Laser IB
Shows the pump laser drive current (mA) of the module
Output Power + / -
Displays output optical power and can adjust the output optical power by
pr/- buttons
Rated Power
Shows the default rated power for the module. The module cannot deliver
output power exceeding the rated power.
Low-cut THRD + / -
Can set the low cut off threshold limit for the EDFA. Pump laser and EDFA
output turns OFF when optical input is less than or equal to the low cut off
threshold value. Default value: -10dBm; Max value: 0dBm; Min value: -
18.5dBm
Serial Number
Shows the module serial number
Hardware Version
Shows the hardware version
Firmware Version
Shows the firmware version
Temperature
Shows the current module temperature (°C)
Running Time
Shows the active run time of the module
Figure 5: LB-1000-EDFA settings - Page 2