background image

MINI COMPRESSOR

 

9

NOTE:

 If the defect persists even after the above steps are taken, contact a service centre. 

15. TABLE OF MALFUNCTIONS

Malfunction

Cause

Removal

compressor does not run switch is in the off position

check the switch (2.)

regulation set to minimum

adjust pressure setting using the adjusting screw (3.)

power cable is not plugged 

in the socket properly

unplug the cable from the socket and replug it

issue with the socket

try connecting a different device to the socket

compressor runs but 

does not achieve the set 

pressure

leaky joints, air hose con-

nected incorrectly

unplug and replug the air hose in accordance with 

point 11. (How to Work with Speed Fittings)

Do not forget to specify the following: 

•  type of defect 

•  product type

•  production year

•  product's serial number (found on the machine plate) 

14. PUTTING INTO OPERATION

1. Interconnect the air supply and beverage supply. 

2. Connect the mini compressor to the power mains.

3. Check that all the joints and connections are sufficiently tight.

4. Turn on the air compressor using the switch and pressurise to the desired pressure. 

WARNING:

   

Use the device only as an accessory to flow-through coolers. Follow the safety 

instructions and do not overload the device. 

LINDR 15

 for pressurising a single beverage line with maximum flow rate of 

40 l/h

LINDR 30

 for pressurising two beverage lines with maximum flow rate of 

120 l/h

.

Summary of Contents for VK 15

Page 1: ...LINDR MINI COMPRESSOR Number 013 2020 REV00 Valid 2020 06 01 INSTRUCTION MANUAL ENGLISH VK15 vk30MINICOMPRESSOR...

Page 2: ...ling and using the device It contains important information necessary to ensure that all operations are done prop erly and safely WARNING Not following instructions may cause injury or damage the devi...

Page 3: ...nection 7 Testing 8 Warranty 9 Device description 10 Connection and pressurisation 11 How to work with speed fittings 12 AIR connection 13 Air pressure adjustment 14 Putting into operation 15 Table of...

Page 4: ...structions WARNING Children aged 15 or more and persons with reduced physical sensory or mental capabilities or insufficient experience and knowledge may only use the device when supervised or instruc...

Page 5: ...situations DANGER Do not use or turn on the device if the power lead cable is damaged 7 TESTING The product is delivered ready for immediate use 8 WARRANTY The device comes with a warranty in accord a...

Page 6: ...DESCRIPTION 1 Air outlet 4 Pressure gauge 2 Switch 5 Power cable 3 Adjusting screw NOTE The VK LINDR mini compressor is primarily designed as an accessory for flow through coolers and beverage keg pre...

Page 7: ...system A system M system 3 F 5 8 x 9 5 mm speed fitting 4 F 5 8 x 8 mm speed fitting 5 VK LINDR mini compressor 6 Beverage 10 2 Connection and Pressurisation by VK LINDR 30 Mini Compressor Two Tap Dev...

Page 8: ...fitting and pull out the hose figure 8 B WARNING If you do not hold the grey ring but pull at the hose the speed fitting will cut even deeper into the hose WARNING Hoses must not be pressurised during...

Page 9: ...nd replug the air hose in accordance with point 11 How to Work with Speed Fittings Do not forget to specify the following type of defect product type production year product s serial number found on t...

Page 10: ...1x a week check that the device is not ex posed to radiant heat 1x a week check that air circulation is not obstructed 1x a year have an engineering inspector check the electrical safety of the device...

Page 11: ...SPECIFICATIONS Name LINDR 15 LINDR 30 Maximum output l hour 40 120 Voltage V Hz 1 220 240 V 50Hz 1 220 240 V 50Hz 1 Input power W W 92 115 Current A A 0 4 0 5 Frame dimensions WxDxH mm 150x240x250 15...

Page 12: ......