![LINDR KCH 01584 Instruction Manual Download Page 7](http://html1.mh-extra.com/html/lindr/kch-01584/kch-01584_instruction-manual_1919610007.webp)
ˇ
7
WARNING:
When unplugging
the device from the socket, grab
the plug and pull it out. Do not under
any circumstances pull at the cable;
risk of damage.
WARNING:
To turn the device off
completely, unplug the appliance from
the power socket.
WARNING:
In the event the
electrical
wiring
of
the
product
becomes damaged, summon a trained
service technician. Do not under any
circumstances
repair
the
device
yourself.
WARNING: The cooling system
contains flammable coolant R290
(propane)!
WARNING:
Emergency
maintenance and repair of the cooling
system must be done by trained,
authorised technicians familiar with
cooling and electrical systems. The
technicians
should
have
special
training and qualification for handling
flammable substances in order to
perform
service
on
coolers
containing
R290
.
Follow
basic
regulations
and
safety
measures
regarding service and repair!
WARNING:
Do not use open
flame or potential sources of sparks in
the vicinity of a cooler using R290
coolant!
WARNING:
After
unpacking,
place the cooler so that heat created
by the cooling unit can be vented
sufficiently.
WARNING:
Do not place objects
that could prevent air circulation on top
of the cooler.
5. Installation and Placement
Place the cooler on a horizontally level,
stable surface (maximum permitted
inclination of 2°). The device requires
sufficient free space around it to allow
air circulation.
-
Ensure sufficient space for air
circulation and heat dissipation.
-
Ensure sufficient access to
fresh air.
-
The device must not be placed
in an enclosed space.
-
The device must not be placed
in proximity to heat sources or
exposed to direct sunlight.
Minimum distance of vents from an
obstacle
that
would
prevent
air
circulation is 20 cm. In places where
there are no vents, minimum distance
is 7 cm. The device is best used in a
cool, well ventilated room. The device
is designed for use at ambient
temperature of 16°C – 32°C
.
The
device
MUST NOT be used or stored
at ambient temperature lower than 0
°C.
The device is designed for use in a
normal environment, always indoors,
protected
from
rain
or
sunlight.
Climate class N.
Summary of Contents for KCH 01584
Page 10: ...10 10 Package Contents The package contains 1 Tap 2 Tap wrench 3 Drip tray and sieve...
Page 14: ...14 12 2 Outlet for beverage Screw an F 5 8 x 3 8 9 5 mm speed fitting onto the keg coupler...
Page 16: ...16...
Page 17: ...17 14 Inlet and Outlet Marking Tap outlet 1 Tap outlet 2...
Page 19: ...19...
Page 20: ...20 2 Keg untapping...
Page 21: ...21 A system keg coupler...
Page 22: ...22 Procedure for tapping and untapping a keg with an A system keg coupler 1 Keg tapping...
Page 23: ...23 2 Keg untapping...
Page 30: ...30...
Page 33: ...33 30 Wiring Diagram...
Page 34: ...34 31 Cooling Diagram...
Page 35: ...35...
Page 36: ...36...