16. Putting into Operation
1.
Connect air supply and beverage supply according to point 13.
2.
Set the thermostat to 0 position.
3.
Connect the cooler to the power mains.
4.
Tap the keg in accordance with point 15.
5.
Turn the air compressor on using the switch and pressurise it to the
required pressure of 1.0-3.4 bar (in models with built-in
compressor, pressure is automatically set to 2.8-3.4 bar).
6.
Check that all the joints and connections are sufficiently tightened.
WARNING:
If leakage is found, untap the keg according to
point 15 and turn off the device. Fix any leaks found on the tubing.
If a leak is found inside the device or you are unsure how to
proceed, contact a service centre.
7.
Use the bar tap to pour out some of the beverage and check that
there is no water left in the device.
WARNING
: If there is water in the device, do not turn it on.
The water might freeze in the beverage tubing and damage the
device.
8.
Set the desired temperature on the thermostat
–
see point 18.
9.
The beverage is now cooling; once cooled (ca. 5-10 minutes) you
can start pouring the first drink.
Summary of Contents for KCH 01584
Page 10: ...10 10 Package Contents The package contains 1 Tap 2 Tap wrench 3 Drip tray and sieve...
Page 14: ...14 12 2 Outlet for beverage Screw an F 5 8 x 3 8 9 5 mm speed fitting onto the keg coupler...
Page 16: ...16...
Page 17: ...17 14 Inlet and Outlet Marking Tap outlet 1 Tap outlet 2...
Page 19: ...19...
Page 20: ...20 2 Keg untapping...
Page 21: ...21 A system keg coupler...
Page 22: ...22 Procedure for tapping and untapping a keg with an A system keg coupler 1 Keg tapping...
Page 23: ...23 2 Keg untapping...
Page 30: ...30...
Page 33: ...33 30 Wiring Diagram...
Page 34: ...34 31 Cooling Diagram...
Page 35: ...35...
Page 36: ...36...